DataSheet.es    


PDF PBA10F Data sheet ( Hoja de datos )

Número de pieza PBA10F
Descripción AC-DC Power Supplies Enclosed type
Fabricantes COSEL 
Logotipo COSEL Logotipo



Hay una vista previa y un enlace de descarga de PBA10F (archivo pdf) en la parte inferior de esta página.


Total 14 Páginas

No Preview Available ! PBA10F Hoja de datos, Descripción, Manual

AC-DC Power Supplies Enclosed type
Ordering information
PBA10FPPBBAA//PPBW
PB A 10 F -O -O
123456
R
Recommended EMI/EMC Filter
NAC-06-472
1Series name
2Single output
3Output wattage
4Universal input
5Output voltage
6Optional *5
C :with Coating
G :Low leakage current
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The EMI/EMC Filter is recommended
*to connect with several devices.
E :Low leakage current
and EMI class A
T :Vertical terminal block
J :Connector type
N :with Cover
(UL508 is acquired)
N1 :with DIN rail and Cover
V :Output voltage setting
potentiometer external-
ly
Cover is optional
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
PBA10F-5
10
5V 2A
PBA10F-12
10.8
12V 0.9A
PBA10F-24
12
24V 0.5A
SPECIFICATIONS
MODEL
PBA10F-5
PBA10F-12
PBA10F-24
VOLTAGE[V]
AC85 - 264 1f or DC110 - 370 (AC50 or DC70 Please refer to the instruction manual 2.1 Input voltage *3)
CURRENT[A]
ACIN 100V 0.30typ (Io=100%)
ACIN 200V 0.20typ (Io=100%)
FREQUENCY[Hz]
50/60 (47 - 440) or DC
INPUT
EFFICIENCY[%]
ACIN 100V 74typ
ACIN 200V 74typ
76typ
76typ
77typ
77typ
INRUSH CURRENT[A]
ACIN 100V
ACIN 200V
15typ (Io=100%)
30typ (Io=100%)
LEAKAGE CURRENT[mA] 0.15/0.30max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1,DENAN)
VOLTAGE[V]
5
12 24
CURRENT[A]
2
0.9 0.5
LINE REGULATION[mV] *6 20max
48max
96max
LOAD REGULATION[mV] *6 40max
100max
150max
RIPPLE[mVp-p]
0 to +50C*1 80max
-10 - 0C*1 140max
120max
160max
120max
160max
OUTPUT
RIPPLE NOISE[mVp-p]
0 to +50C*1
-10 - 0C*1
120max
160max
150max
180max
150max
180max
TEMPERATURE REGULATION[mV]
0 to +50C
-10 to +50C
50max
60max
120max
150max
240max
290max
DRIFT[mV]
*2 20max
48max
96max
START-UP TIME[ms]
200typ(ACIN 100V, Io=100%) *Start-up time is 700ms typ for less than 1minute of applying input again from turning off the input voltage.
HOLD-UP TIME[ms]
20typ (ACIN 100V, Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 4.50 - 5.50
10.0 - 13.2
19.2 - 27.0
OUTPUT VOLTAGE SETTING[V] 5.00 - 5.15
12.00 - 12.48
24.00 - 24.96
OVERCURRENT PROTECTION Works over 105% of rated current and recovers automatically
PROTECTION
CIRCUIT AND
OTHERS
OVERVOLTAGE PROTECTION[V]
OPERATING INDICATION
5.75 - 7.00
LED (Green)
15.0 - 18.0
REMOTE ON/OFF
None
30.0 - 37.0
INPUT-OUTPUT
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)
ISOLATION INPUT-FG
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)
OUTPUT-FG
AC500V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At Room Temperature)
OPERATING TEMP.,HUMID.AND ALTITUDE -10 to +71C (Required Derating), 20 - 90%RH (Non condensing) 3,000m (10,000feet) max
ENVIRONMENT
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
-20 to +75C, 20 - 90%RH (Non condensing) 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis
IMPACT
196.1m/s2 (20G), 11ms, once each X, Y and Z axis
SAFETY AND AGENCY APPROVALS (At only AC input) UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN
NOISE
CONDUCTED NOISE
Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-B
REGULATIONS HARMONIC ATTENUATOR Complies with IEC61000-3-2 (Not built-in to active filter *4) *7
OTHERS
CASE SIZE/WEIGHT
COOLING METHOD
31X78X68mm [1.22X3.07X2.68 inches] (without terminal block) (WXHXD) / 150g max (with cover : 180g max)
Convection
*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN
:RM101).
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.
*3 Derating is required.
*4 When two or more units are used,they may not comply with the harmonic attenuator. Please
contact us for details.
*5 Please contact us about safety approvals for the model with option.
*6 Please contact us about dynamic load and input response.
*7 Please contact us about class C.
* Parallel operation with other model is not possible.
* Derating is required when operated with cover.
* A sound may occur from power supply at peak loading.
PBA/PBWW--22

1 page




PBA10F pdf
AC-DC Power Supplies Enclosed type
Ordering information
PBA30FPPBBAA//PPBW
PB A 30 F -O -O
123456
R
Recommended EMI/EMC Filter
NAC-06-472
1Series name
2Single output
3Output wattage
4Universal input
5Output voltage
6Optional *5
C :with Coating
G :Low leakage current
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The EMI/EMC Filter is recommended
*to connect with several devices.
E :Low leakage current
and EMI class A
T :Vertical terminal block
J :Connector type
N :with Cover
(UL508 is acquired
[5V, 12V, 24V])
N1 :with DIN rail and Cover
V :Output voltage setting
potentiometer external-
ly
Cover is optional
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
PBA30F-3R3
19.8
3.3V 6A
PBA30F-5
30
5V 6A
PBA30F-9
30.6
9V 3.4A
PBA30F-12
30
12V 2.5A
PBA30F-15
30
15V 2A
PBA30F-24
31.2
24V 1.3A
PBA30F-48
31.2
48V 0.65A
SPECIFICATIONS
MODEL
PBA30F-3R3 PBA30F-5
PBA30F-9
PBA30F-12 PBA30F-15 PBA30F-24 PBA30F-48
VOLTAGE[V]
CURRENT[A]
AC85 - 264 1f or DC110 - 370 (AC50 or DC70 Please refer to the instruction manual 2.1 Input voltage *3)
ACIN 100V 0.50typ (Io=100%) 0.70typ (Io=100%)
ACIN 200V 0.30typ (Io=100%) 0.40typ (Io=100%)
FREQUENCY[Hz]
50/60 (47 - 440) or DC
INPUT
EFFICIENCY[%]
ACIN 100V 68typ
ACIN 200V 69typ
74typ
77typ
75typ
77typ
76typ
78typ
78typ
81typ
78typ
81typ
79typ
81typ
INRUSH CURRENT[A]
ACIN 100V
ACIN 200V
15typ (Io=100%) (At cold start)
30typ (Io=100%) (At cold start)
LEAKAGE CURRENT[mA] 0.30/0.65max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1,DENAN)
VOLTAGE[V]
3.3 5 9 12 15 24 48
CURRENT[A]
6 6 3.4 2.5 2 1.3 0.65
LINE REGULATION[mV] *6 20max
20max
36max
48max
60max
96max
192max
LOAD REGULATION[mV] *6 40max
40max
100max
100max
120max
150max
240max
RIPPLE[mVp-p]
0 to +50C*1 80max
-10 - 0C*1 140max
80max
140max
120max
160max
120max
160max
120max
160max
120max
160max
150max
200max
OUTPUT
RIPPLE NOISE[mVp-p]
0 to +50C*1
-10 - 0C*1
120max
160max
120max
160max
150max
180max
150max
180max
150max
180max
150max
180max
250max
300max
TEMPERATURE REGULATION[mV]
0 to +50C
-10 to +50C
50max
60max
50max
60max
90max
120max
120max
150max
150max
180max
240max
290max
480max
600max
DRIFT[mV]
*2 20max
20max
36max
48max
60max
96max
192max
START-UP TIME[ms]
HOLD-UP TIME[ms]
200typ(ACIN 100V, Io=100%) *Start-up time is 700ms typ for less than 1minute of applying input again from turning off the input voltage.
20typ (ACIN 100V, Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 2.85 - 3.60
4.50 - 5.50
7.50 - 10.0
10.0 - 13.2
13.2 - 18.0
19.2 - 27.0
39.0 - 53.0
OUTPUT VOLTAGE SETTING[V] 3.30 - 3.40
5.00 - 5.15
9.00 - 9.36
12.00 - 12.48 15.00 - 15.60 24.00 - 24.96 48.00 - 49.92
OVERCURRENT PROTECTION Works over 105% of rated current and recovers automatically
PROTECTION
CIRCUIT AND
OTHERS
OVERVOLTAGE PROTECTION[V]
OPERATING INDICATION
4.00 - 5.25
LED (Green)
5.75 - 7.00
11.5 - 14.0
15.0 - 18.0
REMOTE ON/OFF
None
20.0 - 25.0
30.0 - 37.0
58.0 - 65.0
INPUT-OUTPUT
ISOLATION INPUT-FG
OUTPUT-FG
OPERATING TEMP.,HUMID.AND ALTITUDE
ENVIRONMENT
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)
AC500V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At Room Temperature)
-10 to +71C (Required Derating), 20 - 90%RH (Non condensing) 3,000m (10,000feet) max
-20 to +75C, 20 - 90%RH (Non condensing) 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis
IMPACT
196.1m/s2 (20G), 11ms, once each X, Y and Z axis
SAFETY AND AGENCY APPROVALS (At only AC input)
NOISE
CONDUCTED NOISE
REGULATIONS HARMONIC ATTENUATOR
OTHERS
CASE SIZE/WEIGHT
COOLING METHOD
UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN
Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-B
Complies with IEC61000-3-2 (Not built-in to active filter *4) *7
31X78X103mm [1.22X3.07X4.06 inches] (without terminal block) (WXHXD) / 270g max (with cover : 310g max)
Convection
*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN
:RM101).
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.
*3 Derating is required.
*4 When two or more units are used,they may not comply with the harmonic attenuator. Please
contact us for details.
*5 Please contact us about safety approvals for the model with option.
*6 Please contact us about dynamic load and input response.
*7 Please contact us about class C.
* Parallel operation with other model is not possible.
* Derating is required when operated with cover.
* A sound may occur from power supply at peak loading.
PBA/PBWW--66

5 Page





PBA10F arduino
AC-DC Power Supplies Enclosed type
Ordering information
PBA100FPPBBAA//PPBW
PB A 100 F -5 -O
123456
R
Recommended EMI/EMC Filter
NAC-06-472
1Series name
2Single output
3Output wattage
4Universal input
5Output voltage
6Optional *5
C :with Coating
G :Low leakage current
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The EMI/EMC Filter is recommended
*to connect with several devices.
(0.15mA max / ACIN 240V)
E :Low leakage current
and EMI class A
(0.5mA max / ACIN 240V)
T :Vertical terminal block
J :Connector type
(Only -12,-15,-24,-36,-48)
R :with Remote ON/OFF
N :with Cover
(Only 24V UL508 is acquired)
N1 :with DIN rail and Cover
V :Output voltage setting
potentiometer external-
ly
Cover is optional
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
PBA100F-3R3 PBA100F-5
66 100
3.3V 20A
5V 20A
PBA100F-9
94.5
9V 10.5A
PBA100F-12
102
12V 8.5A
PBA100F-15
105
15V 7A
PBA100F-24
108
24V 4.5A
PBA100F-36
100.8
36V 2.8A
PBA100F-48
100.8
48V 2.1A
SPECIFICATIONS
MODEL
PBA100F-3R3 PBA100F-5 PBA100F-9 PBA100F-12 PBA100F-15 PBA100F-24 PBA100F-36 PBA100F-48
VOLTAGE[V]
AC85 - 264 1f or DC120 - 370 (AC50 or DC70 Please refer to the instruction manual 2.1 Input voltage *4)
CURRENT[A]
ACIN 100V 0.9typ
ACIN 200V 0.5typ
1.3typ
0.7typ
FREQUENCY[Hz]
50/60 (47 - 63)
INPUT
EFFICIENCY[%]
ACIN 100V 77typ
ACIN 200V 79typ
82typ
84typ
80typ
82typ
81typ
83typ
83typ
86typ
84typ
86typ
84typ
86typ
84typ
86typ
POWER FACTOR(Io=100%)
ACIN 100V
ACIN 200V
0.98typ
0.87typ
0.99typ
0.93typ
INRUSH CURRENT[A]
ACIN 100V
ACIN 200V
20typ (Io=100%) (At cold start)
40typ (Io=100%) (At cold start)
LEAKAGE CURRENT[mA]
0.4/0.75max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1,DENAN)
VOLTAGE[V]
3.3 5 9 12 15 24 36 48
CURRENT[A]
20
20
10.5 8.5
7
4.5 2.8 2.1
LINE REGULATION[mV]
20max
20max
36max
48max
60max
96max
144max
192max
LOAD REGULATION[mV]
40max
40max
100max
100max
120max
150max
240max
240max
RIPPLE[mVp-p]
0 to +50C*1 80max
-10 - 0C*1 140max
80max
140max
120max
160max
120max
160max
120max
160max
120max
160max
150max
200max
150max
200max
OUTPUT
RIPPLE NOISE[mVp-p]
0 to +50C*1
-10 - 0C*1
120max
160max
120max
160max
150max
180max
150max
180max
150max
180max
150max
180max
250max
300max
250max
300max
TEMPERATURE REGULATION[mV]
0 to +50C
-10 to +50C
50max
60max
50max
60max
90max
120max
120max
150max
150max
180max
240max
290max
360max
450max
480max
600max
DRIFT[mV]
*2 20max
20max
36max
48max
60max
96max
144max
192max
START-UP TIME[ms]
350typ(ACIN 100V, Io=100%)
HOLD-UP TIME[ms]
20typ (ACIN 100V, Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 2.85 - 3.63 4.00 - 5.50 7.50 - 10.0 10.0 - 13.2 13.2 - 18.0 19.2 - 27.0 28.8 - 39.6 39.0 - 53.0
OUTPUT VOLTAGE SETTING[V] 3.20 - 3.40 5.00 - 5.15 9.00 - 9.36 12.00 - 12.48 15.00 - 15.60 24.00 - 24.96 36.00 - 37.44 48.00 - 49.92
OVERCURRENT PROTECTION Works over 105% of rated current and recovers automatically
PROTECTION OVERVOLTAGE PROTECTION[V]
CIRCUIT AND OPERATING INDICATION
OTHERS
REMOTE SENSING
4.00 - 5.25 5.75 - 7.00 11.5 - 14.0
LED (Green)
Optional (Only -3R3, -5 Option -K)
15.0 - 18.0
20.0 - 25.0
30.0 - 37.0
43.0 - 50.0
58.0 - 65.0
REMOTE ON/OFF
Optional (Required external power source)
INPUT-OUTPUT -RC
ISOLATION INPUT-FG
*3 AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)
OUTPUT-RC-FG
*3 AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At Room Temperature)
OPERATING TEMP.,HUMID.AND ALTITUDE -10 to +71C (Required Derating), 20 - 90%RH (Non condensing) 3,000m (10,000feet) max
ENVIRONMENT
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
-20 to +75C, 20 - 90%RH (Non condensing) 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axis
IMPACT
196.1m/s2 (20G), 11ms, once each X, Y and Z axis
SAFETY AND AGENCY APPROVALS (At only AC input) UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN
NOISE
CONDUCTED NOISE
Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-B
REGULATIONS HARMONIC ATTENUATOR
Complies with IEC61000-3-2 *6
OTHERS
CASE SIZE/WEIGHT
COOLING METHOD
32X93X147mm [1.26X3.66X5.79 inches] (without terminal block) (WXHXD) / 440g max (with cover : 500g max)
Convection
*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN
:RM101).
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.
*3 Applicable when Remote ON/OFF(optional) is added. RC is insulated with input, output and
FG.
*4 Derating is required.
*5 Please contact us about safety approvals for the model with option.
*6 Please contact us about class C.
* Parallel operation with other model is not possible.
* Derating is required when operated with cover.
* A sound may occur from power supply at peak loading.
PBA/PBWW--1122

11 Page







PáginasTotal 14 Páginas
PDF Descargar[ Datasheet PBA10F.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
PBA100FPBA100FTotal Power International
Total Power International
PBA10FAC-DC Power Supplies Enclosed typeCOSEL
COSEL
PBA10F-12AC-DC Power Supplies Enclosed typeCOSEL
COSEL
PBA10F-24AC-DC Power Supplies Enclosed typeCOSEL
COSEL

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar