ICX204AL
Diagonal 6mm (Type 1/3) Progressive Scan CCD Image Sensor with Square Pixel for B/W Cameras
Description
The ICX204AL is a diagonal 6mm (Type 1/3)
interline CCD solid-state image sensor with a square
pixel array and 800K effective pixels. Progressive
scan allows all pixels' signals to be output
independently. Also, the adoption of high frame rate
readout mode supports 60 frames per second. This
chip features an electronic shutter with variable
charge-storage time which makes it possible to
realize full-frame still image without a mechanical
shutter. Further, high sensitivity and low dark current
are achieved through the adoption of HAD (Hole-
Accumulation Diode) sensors.
This chip is suitable for applications such as FA
cameras, two-dimensional bar-code reader, etc.
16 pin DIP (Plastic)
Features
Progressive scan allows individual readout of the
image signals from all pixels.
High horizontal and vertical resolution (both approx.
768TV-lines) still image without a mechanical shutter.
Supports high frame rate readout mode
(effective 256 lines output, 15MHz drive: 45 frame/s,
20MHz drive: 60 frame/s)
Square pixel
Horizontal drive frequency: Typ.: 15MHz, Max.: 20MHz
No voltage adjustments
(reset gate and substrate bias are not adjusted.)
High resolution, high sensitivity, low dark current
Low smear, excellent antiblooming characteristics
Continuous variable-speed shutter
Recommended range of exit pupil distance: –20 to –100mm
Pin 1
2
V
3
Pin 9
H
7
40
Optical black position
(Top View)
Device Structure
Interline CCD image sensor
Image size:
Total number of pixels:
Number of effective pixels:
Number of active pixels:
Chip size:
Unit cell size:
Optical black:
Number of dummy bits:
Substrate material:
Diagonal 6mm (Type 1/3)
1077 (H) × 788 (V) approx. 850K pixels
1034 (H) × 779 (V) approx. 800K pixels
1024 (H) × 768 (V) approx. 790K pixels (diagonal 5.952mm)
5.80mm (H) × 4.92mm (V)
4.65µm (H) × 4.65µm (V)
Horizontal (H) direction: Front 3 pixels, rear 40 pixels
Vertical (V) direction: Front 7 pixels, rear 2 pixels
Horizontal 29
Vertical 1
Silicon
Sony reserves the right to change products and specifications without prior notice. This information does not convey any license by
any implication or otherwise under any patents or other right. Application circuits shown, if any, are typical examples illustrating the
operation of the devices. Sony cannot assume responsibility for any problems arising out of the use of these circuits.
–1–
E98809B28

1 page




ICX204AL pdf
ICX204AL
Clock Equivalent Circuit Constant
Item Symbol
CφV1
Capacitance between vertical transfer clock and CφV2A
GND
CφV2B
CφV3
CφV12A
CφV2B1
Capacitance between vertical transfer clocks
CφV2A3
CφV32B
CφV13
CφV2A2B
Capacitance between horizontal transfer clock
and GND
CφH1, CφH2
Capacitance between horizontal transfer clocks CφHH
Capacitance between reset gate clock and GND CφRG
Capacitance between substrate clock and GND CφSUB
R1
Vertical transfer clock series resistor
R2A
R2B
R3
Vertical transfer clock ground resistor
RGND
Horizontal transfer clock series resistor
RφH
Min. Typ. Max. Unit Remarks
1500
pF
1800
pF
2700
pF
2200
pF
390 pF
680 pF
560 pF
1000
pF
1800
pF
33 pF
18 pF
43 pF
3 pF
390 pF
91
68
62
30
43
10
Vφ1
R1
CφV12A
Vφ2A
R2A
CφV2B1
CφV1
CφV2A
CφV2A3
CφV2A2B
R2B
CφV2B RGND CφV3
CφV32B
CφV13
R3
Vφ2B
Vφ3
Vertical transfer clock equivalent circuit
RφH
Hφ1
CφH1
CφHH
RφH
Hφ2
CφH2
Horizontal transfer clock equivalent circuit
5

5 Page





ICX204AL arduino
Measurement conditions
ICX204AL
1) In the following measurements, the device drive conditions are at the typical values of the progressive scan
mode, bias and clock voltage conditions.
2) In the following measurements, spot blemishes are excluded and, unless otherwise specified, the optical
black level (OB) is used as the reference for the signal output, which is taken as the value measured at
point [B] of the measurement system.
Definition of standard imaging conditions
1) Standard imaging condition I:
Use a pattern box (luminance: 706cd/m2, color temperature of 3200K halogen source) as a subject. (Pattern
for evaluation is not applicable.) Use a testing standard lens with CM500S (t = 1.0mm) as an IR cut filter
and image at F8. The luminous intensity to the sensor receiving surface at this point is defined as the
standard sensitivity testing luminous intensity.
2) Standard imaging condition II:
Image a light source (color temperature of 3200K) with a uniformity of brightness within 2% at all angles.
Use a testing standard lens with CM500S (t = 1.0mm) as an IR cut filter. The luminous intensity is adjusted
to the value indicated in each testing item by the lens diaphragm.
3) Standard imaging condition III:
Image a light source (color temperature of 3200K) with a uniformity of brightness within 2% at all angles.
Use a testing standard lens (exit pupil distance 33mm) with CM500S (t = 1.0mm) as an IR cut filter. The
luminous intensity is adjusted to the value indicated in each testing item by the lens diaphragm.
1. Sensitivity
Set to standard imaging condition I. After selecting the electronic shutter mode with a shutter speed of
1/250s, measure the signal outputs (VS) at the center of screen, and substitute the values into the following
formulas.
S = VS ×
250
30
[mV]
2. Saturation signal
Set to standard imaging condition II. After adjusting the luminous intensity to 10 times the intensity with the
average value of the signal output, 150mV, measure the minimum values of the signal output.
3. Smear
Set to standard imaging condition II. With the lens diaphragm at F5.6 to F8, first adjust the luminous
intensity to 500 times the intensity with the average value of the signal output, 150mV. Then after the
readout clock is stopped and the charge drain is executed by the electronic shutter at the respective H
blankings, measure the maximum value (VSm [mV]) of the signal output, and substitute the values into the
following formula.
Sm =
Vsm
150
×
1
500
×
1
10
× 100 [%] (1/10V method conversion value)
11

11 Page







PáginasTotal 22 Páginas
PDF Descargar[ Datasheet ICX204AL.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
ICX204AKCCD Image Sensor for NTSC Color Video CamerasSony
Sony
ICX204ALDiagonal 6mm (Type 1/3) Progressive Scan CCD Image SensorSony
Sony

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar