CC3-E DIP/SMD
CC3-E Specifications
5
Input
Output
Function
Environment
Isolation
Standards
Mechanical
Nominal Voltage
Voltage Range
Efficiency (typ)
(*1)
Current (typ)
(*1)
Nominal Voltage
Maximum Current
Maximum Power
(*2)
Maximum Line Regulation(Within input voltage range)
Maximum Load Regulation (0-100% load) (*3)
Temperature Coefficient
(Ambient temperature -40 to +50 )
Max Power Total Regulation (max)(*4)
Maximum Ripple & Noise (typ/max) (*5)
Voltage Adjustable Range
Over Current Protection
(*6)
Over Voltage Protection
Remote ON/OFF Control
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
Vibration
Shock
Withstand Voltage
Isolation Resistance
Safety Standards
Weight (typ)
Size (W x H x D)
V
V
A
VDC
A
mV
mV
mVp-p
VDC
RH
RH
g
mm
73 77
0.723
0.779
3.3 5
0.800
0.600
2.64
20
40
DC5.0
DC4.5-9.0
82
0.732
12 15
0.250
0.200
3
40
100
12
0.125
81
0.741
15
0.100
80
600
80mV
200mV
300mV
35
40/120
30/120
3.15-3.6
4.75-6.0
11.4-15.0
11.4- 15.0
Available
Not available
Available
-40 to +85
-40 to +85
5-95 (the conditions of maximum 38 in wet bulb temperature and non-condensation should be ensured.)
5-95 (the conditions of maximum 38 in wet bulb temperature and non-condensation should be ensured.)
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, X/Y/Z 3 directions, 2h for each
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50M min
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
4.5
DIP: 22.86 x 8.5 x 16.6 / SMD: 22.86 x 8.8 x 16.6
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25 C, if not specified separately.
Note: For 12V/ 12V models, output power can be set to 15V/ 15V by connecting the output adjustment terminal TRM to -Vout.
Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25 C.
(*2) The maximum output power value is between -40 C and +50 C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25 C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
Input
Output
Function
Environment
Isolation
Standards
Mechanical
Nominal Voltage
Voltage Range
Efficiency (typ)
(*1)
Current (typ)
(*1)
Nominal Voltage
Maximum Current
Maximum Power
(*2)
Maximum Line Regulation(Within input voltage range)
Maximum Load Regulation (0-100% load) (*3)
Temperature Coefficient
(Ambient temperature -40 to +50 )
Max Power Total Regulation (max)(*4)
Maximum Ripple & Noise (typ/max) (*5)
Voltage Adjustable Range
Over Current Protection
(*6)
Over Voltage Protection
Remote ON/OFF Control
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
Vibration
Shock
Withstand Voltage
Isolation Resistance
Safety Standards
Weight (typ)
Size (W x H x D)
V
V
A
VDC
A
W
mV
mV
mVp-p
VDC
RH
RH
g
mm
74 79
0.297
0.316
3.3 5
0.800
0.600
2.64
20
40
DC12
DC9.0-18
82
0.305
12 15
0.250
0.200
3
40
100
12
0.125
81
0.309
15
0.100
80
600
80mV
200mV
300mV
35
40/120
30/120
3.15-3.6
4.75-6.0
11.4-15.0
11.4- 15.0
Available
Not available
Available
-40 to +85
-40 to +85
5-95 (the conditions of maximum 38 C in wet bulb temperature and non-condensation should be ensured.)
5-95 (the conditions of maximum 38 C in wet bulb temperature and non-condensation should be ensured.)
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, X/Y/Z 3 directions, 2h for each
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50M min
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
4.5
DIP: 22.86 x 8.5 x 16.6 / SMD: 22.86 x 8.8 x 16.6
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25 C, if not specified separately.
Note: For 12V/ 12V models, output power can be set to 15V/ 15V by connecting the output adjustment terminal TRM to -Vout.
Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25 C.
(*2) The maximum output power value is between -40 C and +50 C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25 C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.

5 Page





CC3-1212SS-E arduino
CC6-E
CC6-E Specifications
11
Input
Output
Function
Environment
Isolation
Standards
Mechanical
Nominal Voltage
Voltage Range
Efficiency (typ)
(*1)
Current (typ)
(*1)
Nominal Voltage
Maximum Current
Maximum Power
(*2)
Maximum Line Regulation(Within input voltage range)
Maximum Load Regulation (0-100% load) (*3)
Temperature Coefficient
(Ambient temperature -40 to +50 )
Max Power Total Regulation (max)(*4)
Maximum Ripple & Noise (typ/max) (*5)
Voltage Adjustable Range
Over Current Protection
(*6)
Over Voltage Protection
Remote ON/OFF Control
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
Vibration
Shock
Withstand Voltage
Isolation Resistance
Safety Standards
Weight (typ)
Size (W x H x D)
V
V
A
VDC
A
W
mV
mV
mVp-p
VDC
RH
RH
g
mm
76 79
1.042
1.266
3.3 5
1.200
1.000
3.96 5
20
40
DC5.0
DC4.5-9.0
82
1.463
12 15
12 15
0.500
0.400
0.250
0.200
6
40 80
100 600
80mV
200mV
300mV
35
40/120
30/120
3.15-3.6
4.75-6.0
11.4-15.0
11.4- 15.0
Available
Not available
Available
-40 to +85
-40 to +85
5-95 (the conditions of maximum 38 in wet bulb temperature and non-condensation should be ensured.)
5-95 (the conditions of maximum 38 in wet bulb temperature and non-condensation should be ensured.)
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50M min
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
5.8
DIP: 22.86 x 8.5 x 21.1 / SMD: 22.86 x 8.8 x 21.1
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25 C, if not specified separately.
Note: For 12V/ 12V models, output power can be set to 15V/ 15V by connecting the output adjustment terminal TRM to -Vout.
Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25 C.
(*2) The maximum output power value is between -40 C and +50 C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25 C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
Input
Output
Function
Environment
Isolation
Standards
Mechanical
Nominal Voltage
Voltage Range
Efficiency (typ)
(*1)
Current (typ)
(*1)
Nominal Voltage
Maximum Current
Maximum Power
(*2)
Maximum Line Regulation(Within input voltage range)
Maximum Load Regulation (0-100% load) (*3)
Temperature Coefficient
(Ambient temperature -40 to +50 )
Max Power Total Regulation (max)(*4)
Maximum Ripple & Noise (typ/max) (*5)
Voltage Adjustable Range
Over Current Protection
(*6)
Over Voltage Protection
Remote ON/OFF Control
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
Vibration
Shock
Withstand Voltage
Isolation Resistance
Safety Standards
Weight (typ)
Size (W x H x D)
V
V
A
VDC
A
W
mV
mV
mVp-p
VDC
RH
RH
g
mm
78
0.423
3.3
3.96
1.200
20
40
82
0.610
5
DC12
DC9.0-18
85
0.588
12 15
12 15
0.500
0.400
0.250
0.200
6
40 80
100 600
80mV
200mV
300mV
35
40/120
30/120
3.15-3.6
4.75-6.0
11.4-15.0
11.4- 15.0
Available
Not available
Available
-40 to +85
-40 to +85
5-95 (the conditions of maximum 38 C in wet bulb temperature and non-condensation should be ensured.)
5-95 (the conditions of maximum 38 C in wet bulb temperature and non-condensation should be ensured.)
10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50M min
UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
5.8
DIP: 22.86 x 8.5 x 21.1 / SMD: 22.86 x 8.8 x 21.1
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25 C, if not specified separately.
Note: For 12V/ 12V models, output power can be set to 15V/ 15V by connecting the output adjustment terminal TRM to -Vout.
Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25 C.
(*2) The maximum output power value is between -40 C and +50 C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25 C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.

11 Page







PáginasTotal 25 Páginas
PDF Descargar[ Datasheet CC3-1212SS-E.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
CC3-1212SS-EInsulation type DC-DC converterTDK-Lambds
TDK-Lambds

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar