SD705/ 706/ 707/ 708: FAMILY OF TINY ROBUST SINGLE
AXIS GYROSCOPES FOR HIGH END APPLICATIONS
The low cost gyroscopes with SP-Interface provide a stable rate signal in the short as well as the long time range due to
their good noise performance making them well suited for ambitious measurement and control applications.
Tiny QFN40 package of only 6x6x2 mm³
Temperature operating range -40°C to +85°C
Fully calibrated over the whole operating temperature range
Continuously working self diagnosis
Sensitive gyroscope axis either in-plane or out-of-plane
Simultaneously two measurement ranges of ±100°/s and ±300°/s
Provide over range up to ±128°/s and ±512°/s, respectively
Available as 3.3V or 5V version
PRODUCT SELECTION TABLE
PART NAME GYROSCOPE AXIS
SD705
SD706
SD707
SD708
X
Z
X
Z
SUPPLY VOLTAGE
3.3V
3.3V
5V
5V
OPERATION SPECIFICATION
PARAMETER
MIN
Supply voltage
Supply current
Start up time
SPI communication speed
3.10 (4.75)
100
MAX
3.50 (5.25)
18 (20)
400
10000
UNIT
V
mA
ms
kHz
CONDITION
5V version in brackets
over full temp. range -40 to +85°C
including start up checks
64 bit telegram
GYROSCOPE PERFORMANCE (max values over full temperature range)
PARAMETER
MR1 MR2 UNIT
CONDITION
Calibrated measurement range
Output value range
Resolution
RMS noise
Bandwidth (-3dB)
Zero rate bias at RT
Total zero rate bias
Sensitivity error
Linearity error
Cross axis sensitivity
Recovery time after over range
Acceleration cross sensitivity
± 100
± 300
± 128
± 512
0.0039
0.0156
0.3 0.8
10 75
± 1.5
±5
± 5.0
±1
± 2.0
50
0.1
°/s
°/s
(°/s)/LSB
°/s
Hz
°/s
°/s
%
%
%
ms
°/s/g
True 16 bit
± 25% tolerance
Zero setting at 25°C
Including temperature drift and aging
Versus best fit
Against angular rates about other axis
Time to normal operation after 300 °/s
for MR1 and 900 °/s for MR2
© 2010. Proprietary data. All rights reserved by SensorDynamics AG Entwicklungs- und Produktionsgesellschaft (below SD) including the right to file
industrial property rights. SD retains the sole power of distribution, such as reproduction, copying, distribution, adaptation, merger and translation.
Reproduction, copying, distribution, adaptation, merger and translation, in part or whole, without the prior written consent of SD, is prohibited. The
information given in this document shall in no event be regarded as a guarantee of conditions or characteristics.
SensorDynamics AG I Schloss Eybesfeld 1e. 8403 Lebring I Austria I +49-89-5484-2220 I [email protected] I www.sensordynamics.cc
page 1
1_9b_SD705to708_single_axis_gyroscope_QFN40_V1_0.doc
Free Datasheet http://www.Datasheet4U.com

1 page





PáginasTotal 2 Páginas
PDF Descargar[ Datasheet SD707.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
SD7005FAN CONTROLLERETC
ETC
SD700CSTANDARD RECOVERY DIODES Hockey Puk VersionInternational Rectifier
International Rectifier
SD7012Triple Tone Medoly GeneratorETC
ETC
SD7015Triple Tone Melody Generator With Simple Flash ControlETC
ETC

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar