PDF SWS600 Data sheet ( Hoja de datos )

Número de pieza SWS600
Descripción (SWS300 / SWS600) Single Output General Purpose Power Supplies
Fabricantes Lambda 
Logotipo Lambda Logotipo



Hay una vista previa y un enlace de descarga de SWS600 (archivo pdf) en la parte inferior de esta página.


Total 2 Páginas

No Preview Available ! SWS600 Hoja de datos, Descripción, Manual

SWS300/600 Series
Single Output General Purpose Power Supplies
Features
u Low Cost
u Active Power Factor Correction
u Universal Input (85 - 265VAC)
u Input Transient Protected IEC61000-4
u SEMI F47 Certified (208VAC Input)
u Global safety Approvals
u Level B EMI
Key Market Segments & Applications
Specifications
Model
SWS300
SWS600
Input Voltage range
(1) -
85 - 265VAC (47 - 63Hz) or 120 - 370VDC
Inrush Current (115 / 230VAC)
A
20 / 40 at 25°C, cold start
Power Factor
-
Meets EN61000-3-2
Input Current (100/200VAC)
A
3.6 / 1.8A
7.2 / 3.6A
Temperature Coefficient
-
<0.02%/°C
Overcurrent Protection
-
>105%, Constant current style
Overvoltage Protection
V
3.3V: 4.1-5.3V, 5V: 6.25-7.5V, 12V: 13.8-16.8V
15V: 19.3-24.2V, 24V: 30-34.8V, 36V: 41.4-50.4V, 48V: 60-69.6V
Overtemperature Protection
-
Yes, cycle AC to reset
Hold Up Time (Typ)
ms
20ms at 115/230VAC
Leakage Current (max)
mA
SWS300: 0.75mA , SWS600: 1.5mA
Remote Sense - None
Yes
Parallel Connection
-
None
Yes
Remote On/Off - None
Yes, >4.5V to shutdown
Power Fail Signal
-
None
Yes, open collector output
LED Indicator
-
Green LED = On
Operating Temperature
°C
-10 to +65°C (See table for derating - model specific)
Storage Temperature
°C
-30 to +85°C
Humidity (non-condensing)
-
30 - 90% RH operating, 10 - 95%RH non operating
Cooling
-
Internal fan
Withstand Voltage
- I/P to Grnd 2kVAC, I/P to O/P 3kVAC, O/P to Grnd 500VAC, O/P to CNT 100VAC for 1 min
Isolation Resistance
-
>100M at 25°C & 70%RH, Output to Ground 500VDC
Vibration (non operating)
-
10 - 55Hz (sweep for 1 min)19.6m/s2 constant X, Y, Z 1 hour each plane)
Immunity
-
EN61000-4-2, -3, -4, -5, -6, -8, -11
Safety Agency Approvals
- UL60950-1, CSA60950-1, EN60950-1, EN50178, CE Mark, SEMI F47 (208VAC)
Conducted & Radiated EMI
-
EN55011 / EN55022-B, FCC Class B
Recommended EMI Filter
-
MC1206
MC1210
Weight (Typ)
g 950
2000
Size (WxHxD)
in 2.05 x 4.01 x 7.8”
3.62 x 4.72 x 7.48”
Warranty
yrs
Two Years
Notes:(1) Derate linearly to 80% load from 115VAC to 85VAC input (derate to 90% load for SWS600-5, no derating SWS300, 600-3)
1-800-526-2324 • www.us.tdk-lambda.com/lp/
99 Disclaimer: us.tdk-lambda.com/lp/legal.htm
Free Datasheet http://www.datasheet-pdf.com/

1 page





PáginasTotal 2 Páginas
PDF Descargar[ Datasheet SWS600.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
SWS600(SWS300 / SWS600) Single Output General Purpose Power SuppliesLambda
Lambda

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar