1 Introduction and Use
The digital transducer electronic devices AED9101B belong to the family of
AED components which digitally condition and network as bus-capable signals
from mechanical measured value transducers. This includes digital
measurement amplifier boards, base devices with RS-485 interface, and
intelligent sensors with integrated signal processing. The objective of these
components is the digitization and conditioning of the measuring signals directly
at the transducer location. Via the digital transducer electronics, SG transducers
can be connected directly to a computer or PC within a full bridge circuit. This
enables you to build up complete measurement chains – fast and at low cost.
The basic device AED9101B comprises the measurement amplifier AD 101B.
The basic device provides mechanical protection, shields the measurement
amplifier board (EMC protection), and offers the option to select additionally the
serial interfaces RS422 (factory setting), RS 485, or RS232.
AED9101basic := basic device AED9101B + meas. amplifier AD101B
Part 2 of the operating instructions describes the measurement amplifier board,
and Part 3 details the command set for serial communication.
The transducer electronic devices AED9101B are also abbreviated with AED in
the following text.
1) Strain Gage
AED9101B_P1_e_draft_020318.doc
Free Datasheet http://www.datasheet4u.com/

5 Page





AED9101B arduino
AED9101B / Part 1 / Basic device
10/24
Effect on the measurement result with AUTOCAL (command ACL1)
activated:
6-wire circuit (standard operation mode):
With the 6-wire-circuit the return cable 2´ and 3´ in the load cell ( for load cells
with 6-wire-connection) or directly on the load cell connection ( for load cells
with 4-wire circuit) with the supply cable 2 and 3 bridged (Fig.3.1.2 ). This
corrects all influences. Even a change of cable length following a calibration
does not lead to any deviations in the measurement results.
4-wire circuit:
With the 4-wire-circuit the return cable 2´ and 3´ on the connection terminals 2
and 3 are connected directly to the AED (Fig.3.1.3 ). As the correction by
AUTOCAL can only be effected up to the return points 2´, 3´, all changes in
cable resistance are reflected in the measurement result. That is, even if the 4-
wire cable used for a calibration is no longer changed, there still result
measurement errors in conditions with changing temperatures, caused by the
temperature-dependent cable resistance and possibly also by transitory
resistances in the connectors.
AED9101B_P1_e_draft_020318.doc
Free Datasheet http://www.datasheet4u.com/

11 Page







PáginasTotal 24 Páginas
PDF Descargar[ Datasheet AED9101B.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
AED9101BOperating manualHBM
HBM

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar