Número de pieza | TFS70H12A | |
Descripción | VI TELEFILTER | |
Fabricantes | Tele Filter GmbH | |
Logotipo | ||
Hay una vista previa y un enlace de descarga de TFS70H12A (archivo pdf) en la parte inferior de esta página. Total 4 Páginas | ||
No Preview Available ! tfs70H12A.doc
VI TELEFILTER
Filter Specification
Version 1.0
25.07.2000
TFS 70H12A - 1/4
1. Measurement condition
Ambient temperature TA:
Input power level:
Terminating impedances in fc:
25 °C.
0 dBm.
for input:
for output:
50 Ω 0 pF.
50 Ω 0 pF.
2. Characteristics
Remark:
Reference level for the relative attenuation arel of the TFS 70H12A is the minimum of the pass band attenuation amin. The minimum of the pass
band attenuation amin is defined as the insertion loss ae. The reference frequence fc is the arithmetic mean value of the upper and lower
frequencies at the 20 dB filter attenuation level relative to the insertion loss ae. The temperature coefficient of frequency Tcf is valid both for the
reference frequency fc and the frequency response of the filter in the operating temperature range. The frequency shift of the filter in the operating
temperature range is not included in the production tolerance scheme.
Data
Insertion loss (Reference level) ae
Centre frequency fc at ambient temperature (fCTA)
Pass band ( PB ) :
Amplitude ripple in : fc - 3,6 MHz ... fc + 3,6 MHz
Bandwidth ( BW ) :
0,8 dB - band width
3 dB - band width
20 dB - band width
40 dB - band width
50 dB - band width
Relative attenuation
arel
fc ± 3,6
fc ± 5,0
fc ± 5,05
fc - 68
fc + 50
fc + 90
fc + 145
fc + 155
fc ..... fc ± 3,6 MHz
MHz ..... fc ± 4,0 MHz
MHz ..... fc ± 5,05 MHz
MHz ..... fc ± 50 MHz
MHz ..... fc - 50 MHz
MHz ..... fc + 90 MHz
MHz ..... fc + 145 MHz
MHz ..... fc + 155 MHz
MHz ..... fc + 210 MHz
Group delay ( mean value in PB ):
Group delay ripple in PB (p-p):
Deviation from linear phase in PB :
Triple transit attenuation compared to main signal
Crosstalk
Temperature coefficient of frequency ( Tcf ) :
Frequency deviation of fc over temperature :
Operating temperature range
Storage temperature range
typ. value
tolerance / limit
21 dB
70,0 MHz
max. 23 dB
70 ± 0,08 MHz
0,4 dB
fc - 4,0 MHz ... fc + 4,0 MHz
max. 0,8 dB
at ambient temperature TA
7,45
8,05
9,26
9,88
10,11
MHz
MHz
MHz
MHz
MHz
min. 7,2 MHz
min. 8,0 MHz
max. 10,0 MHz
-
-
45 dB
55...60 dB
45...50 dB
45...55 dB
55...58 dB
25 dB
55...60 dB
max. 0,8 dB
max. 3 dB
min. 40 dB
min. 45 dB
2,43 µs
70...80 ns
3,3 ° (r.m.s. 0,8 °)
max. 2,5 µs
max. 100 ns
max. 4 °
50...52 dB
70...75 dB
-87 ppm/K²
∆fc(Hz) = Tcf(ppm/K) x (T - To) x fCTA (MHz)
- 25 °C ... + 80 °C
- 40 °C ... + 85 °C
Generated:
Checked/Approved:
Wadim Dunzow
Dr. Bert Wall
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
E-Mail: [email protected]
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: [email protected]
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
www.DataSheet4U.net
1 page |
Páginas | Total 4 Páginas | |
PDF Descargar | [ Datasheet TFS70H12A.PDF ] |
Número de pieza | Descripción | Fabricantes |
TFS70H12 | VI TELEFILTER | Tele Filter GmbH |
TFS70H12A | VI TELEFILTER | Tele Filter GmbH |
Número de pieza | Descripción | Fabricantes |
SLA6805M | High Voltage 3 phase Motor Driver IC. |
Sanken |
SDC1742 | 12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters. |
Analog Devices |
DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares, |
DataSheet.es | 2020 | Privacy Policy | Contacto | Buscar |