DataSheet.es    


PDF LC72706 Data sheet ( Hoja de datos )

Número de pieza LC72706
Descripción FM Multiplex Receiver IC Supporting All Worldwide Standards
Fabricantes Sanyo Semicon Device 
Logotipo Sanyo Semicon Device Logotipo



Hay una vista previa y un enlace de descarga de LC72706 (archivo pdf) en la parte inferior de esta página.


Total 15 Páginas

No Preview Available ! LC72706 Hoja de datos, Descripción, Manual

Ordering number : EN5745
CMOS IC
LC72706E
FM Multiplex Receiver IC Supporting
All Worldwide Standards
Overview
The LC72706E is a data demodulation IC for receiving
FM multiplex broadcasts for mobile receivers in the
DARC format. In conjunction with a bandpass filter IC
(either the LV3400M or the LV3403M), the LC72706E
can form a compact yet high-functionality FM multiplex
reception system. This IC supports all the FM multiplex
frame structures (methods A, B, and C) in the ITU-R
recommendations.
Applications
• Receivers for DARC format mobile receiver FM
multiplex broadcasts
Package Dimensions
unit: mm
3148-QFP44MA
[LC72706E]
Functions
• MSK delay detection circuit based on a 1T delay
• Error correction function based on a 2T delay (in the
MSK detector stage)
• Digital PLL based clock regeneration circuit
• Shift-register type 1T and 2T delay circuits
• Block and frame synchronization detection circuit
• Serial control data transfer based support for the A, B,
and C FM multiplex frame structures
• Function for setting the number of allowable BIC errors,
the number of synchronization protection.
• Error correction using (272, 190) codes
• Layer 4 CRC code checking circuit
• On-chip frame memory and memory control circuit for
vertical correction
• 7.2-MHz crystal oscillator circuit
SANYO: QFP44MA
• CCB is a trademark of SANYO ELECTRIC CO., LTD.
• CCB is SANYO’s original bus format and all the bus
addresses are controlled by SANYO.
SANYO Electric Co.,Ltd. Semiconductor Bussiness Headquarters
TOKYO OFFICE Tokyo Bldg., 1-10, 1 Chome, Ueno, Taito-ku, TOKYO, 110-8534 JAPAN
40698RM (OT) No. 5745-1/15

1 page




LC72706 pdf
LC72706E
Data I/O Techniques
• CCB Technique
Sanyo audio ICs input and output data using the Sanyo CCB (computer control bus) standard, which is a serial bus
format. This IC uses an 8-bit address CCB and uses the following addresses.
Address
I/O mode
B0 B1 B2 B3 A0 A1 A2 A3
Function
Input
0 1 0 1 1 1 1 1 16-bit control data input
Output
1 1 0 1 1 1 1 1 Data output for the input clock (CL)
Input
0 0 1 1 1 1 1 1 Data input (in 8-bit units) for the layer 4 CRC check circuit
I/O mode determined
Data Input Timing
Data Output Timing
Internal data latching
Note:The DO pin is normally left open.
Since the DO pin is an n-channel open drain pin, the time required for the data to change from the low level to the high level depends on the value of
the pull-up resistor.
No. 5745-5/15

5 Page





LC72706 arduino
LC72706E
• To prevent unnecessary error correction, the vertical correction is not applied to packets that were fully corrected by
horizontal correction or to packets that had no errors.
• Vertical correction is executed when all packet data in the object data was received while frame synchronization was
established and not all of the packet (block) data was corrected by horizontal correction. Vertical correction is not
performed if a whole frame of data with no errors is received, or if the frame was not synchronized. Also, the
corresponding post-vertical correction output data is not output.
• All data can be output, regardless of the correction complete/incomplete, synchronized/unsynchronized reception,
data/packet status or other conditions by setting bit 5 (INT) in the control register to 1.
CPU Interface Basic Restrictions
To save internal memory, this IC uses the smallest possible output buffer. Since the data that the IC receives is written to
memory without any breaks, if data readout is delayed post-correction data that should be read out will be overwritten by
the next data to be output. The output timings in this IC for post-correction (horizontal and vertical) data are stipulated as
follows.
• When preparation of the output data has completed, the IC issues a transfer request by setting the INT pin low.
• For data output, there are periods in which only horizontal data can be output and periods in which both horizontal data
and vertical data can be output.
• Data transfers must be completed within about 9 ms after the INT pin goes low. For periods in which only post-
horizontal correction data can be output, data can be transferred over a period of about 18 ms. Even if the CPU is in the
midst of a read operation, the next output data will be written to the output buffer after the specified period elapses.
• Only one block of data can be read for a single transfer request (INT) for both vertical and horizontal correction. After
vertical correction processing completes, the post-vertical correction data is output in order starting with block number
1, and the parity block data is not output.
Only horizontal
data output
Horizontal and
vertical data output
Horizontal data
output period
Horizontal data
output period
Period when
data cannot be
guaranteed
Vertical data output period
Figure 2 Basic Interface Timing
Notes on Data Output Timing (The relationship with the received data)
Figure 3 shows the timing relationship between the received data and the interrupt control signal INT. However, the
delay component relative to the actually received signal due to the demodulation operations in the MSK demodulation
block is ignored. Block synchronization is established by recognizing the BIC code. As shown in figure 3, the data for the
nth packet can be output during the reception of the next packet, packet number n + 1.
Figure 4 shows the output timing for vertical correction data. Vertical correction is used when the data for a whole frame
is stored in memory, frame synchronization is established, and furthermore horizontal correction was not able to correct
all the packet data. The timing for the start of vertical correction execution is the head of the frame. During reception of
packets 1 to 28 in the nth frame, horizontal correction is performed on each packet, data is passed to the CPU, and the
remaining unused processing time during that interval is used to apply vertical correction to the data from the previous
frame (frame n – 1). The post-vertical correction data (190 blocks of data) is output in order starting when the 29th packet
(block) is received at the rate of one block of output data for every block received. Of the data in the FM multiplex
broadcast frame structure, only the data in the data blocks is output, and the 190th block (the last data block) is output
while the 218th block is being received. As discussed previously (page 10), of the post-vertical correction output data, the
packet data for which horizontal correction completed fully is not output (the INT signal is not issued). However, it is not
the case that the vertical output is speeded up by the amount of the packet data that is not output. For example, if data
packets 1 to 100 were fully corrected in horizontal correction, the point that the 101st post-vertical correction packet data
is output will not be the reception position block number 29 in figure 4, but the reception position of packet data number
129.
No. 5745-11/15

11 Page







PáginasTotal 15 Páginas
PDF Descargar[ Datasheet LC72706.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
LC72700Mobile FM Multiplex Broadcast Receiver LSISanyo Semicon Device
Sanyo Semicon Device
LC72700EMobile FM Multiplex Broadcast Receiver LSISanyo Semicon Device
Sanyo Semicon Device
LC72700GMobile FM Multiplex Broadcast Receiver LSISanyo Semicon Device
Sanyo Semicon Device
LC72701MSerial Interface DiallerSanyo Semicon Device
Sanyo Semicon Device

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar