No Preview Available ! SAFC315MF70T Hoja de datos, Descripción, Manual

CERAMIC MICROWAVE FILTERS
SAW FILTERS
SAF Series
FEATURES
s Standard part frequency range (80MHz – 2.0GHz)
s Low passband ripple
s Linear phase
s High selectivity
APPLICATIONS
s Cellular Phone: E-AMPS, PCS and GSM, PDC
s Cordless Phone: CT-1, ISM, DECT
s Land Mobile Radio (LMR)
s 915 MHz ISM
s Pager
s RKE
s GPS
PART NUMBERING SYSTEM
SAF
C
860.5M
A* 7* 0*
N – TC
Designates
Saw Filters
C – Surface Mount
Multi-Layered Ceramic
U – Surface Mount
Single Layer Ceramic
Center
Frequency
in MHz
Alpha
Character for
Design
Characteristics
Numeric
Package
Style
Code
Numeric
Performance
Code
Substrate:
T – Lithium
Tantalate
N – Lithium
Niobate
X – Crystal
S – Sapphire
*Consult Microwave Group for details by part number.
180mm dia reels:
TC = 500/Reel
TC11 = 1,000/Reel
TC12 = 2,000/Reel
330mm dia reels:
TC00 = 10,000/Reel
TC05 = 5,000/Reel
TC04 = 4,000/Reel
TC02 = 2,000/Reel
TYPICAL CELLULAR SYSTEM
AND SAW POSSIBILITIES
ATTENUATION VS. FREQUENCY – GENERAL
COMPARISON OF FILTER CHARACTERISTICS
SAW Rx
www.DataSheet4LUN.Acom FILTER
MIXER
SAW
IF
FILTER
ANT
SAW LOCAL
FILTER
DUPLEXER
VCO
LPF
P.S. PLL
P.A.
SAW Tx
MIXER
FILTER
90MHz
PLL
AF
IF
TCXO
SAW
LC
Dielectric
Frequency
350 CG01-I

1 page




SAFC315MF70T pdf
CERAMIC MICROWAVE FILTERS
SAW FILTERS
ENVIRONMENTAL SPECIFICATIONS
SAF Series
MECHANICAL
TEST ITEM
Terminal Strength
Solderability
Random Drop
Vibration
PACKAGE
SMD
LEADED
BOTH
BOTH
BOTH
TEST CONDITIONS
Filter is soldered onto the center of PCB which is laid on two small supporters
spaced 90mm apart. The PCB is deflected to 1mm below the horizontal level by the
pressing stick for 1 second and repeated 5 times.
A force of 1.0 Kg shall be applied to each terminal in the direction of the axis of
terminal for 30 ± 5 seconds.
A force of 250 gf is applied to each lead in axial direction. The lead shall be bent
90 degrees to one direction, then in opposite direction and returned to the
original position.
Lead terminals are immersed in methanol with 7 to 10% of rosin flux for about
5 seconds, then immersed in soldering bath at 230 ± 5°C for 5 ± 0.5 seconds.
Drop 3 times on concrete floor from 1.0 meter, (30cm for some products).
Vibration amplitude of 1.5mm at 10-55Hz in each of three mutually
perpendicular directions for 1 hour.
TEST METHOD
MIL-STD-202E
Method 208C
MIL-STD-201E
Method 201A
ENVIRONMENTAL
TEST ITEM
Salt Spray
Temperature Cycling
Humidity
Operating Humidity
Thermal Shock
Life Test (High)
Life Test (Low)
Operating Life Test
www.DatSauSlfhueraetti4onU.com
Resistance to
Soldering Heat
PACKAGE
BOTH
BOTH
BOTH
BOTH
BOTH
BOTH
BOTH
BOTH
BOTH
SMD
LEADED
TEST CONDITIONS
Hold in chamber with 5% salt density at 35°C +1.1°/–1.7°C for 48 hours.
Measure after exposure to room condition for 1 hour.
Exposure to 5 cycles of –55°C (30 minutes) ¡+25°C (15 minutes), ±85°C
(30 minutes) ¡+25°C (15 minutes). Test after 2 hours exposure to room conditions.
Hold in chamber with 90 to 95% R.H. at 40 ± 2°C for 100 hours. Test after 2
hours exposure to room conditions.
Hold in chamber with 90 to 95% R.H. at 40 ± 2°C for 100 hours at 6VDC.
Test after 2 hours exposure to room conditions.
Expose to 5 cycles of –55°C (30 minutes) ¡+85°C (30 minutes). Test after 2 hours
exposure to room conditions.
Hold in chamber at 85 ± 2°C for 100 hours. Test after exposure to room
conditions for 2 hours.
Hold in chamber at –30 ± 2°C for 100 hours. Test after exposure to room
conditions for 2 hours.
Hold in chamber at 85 ± 2°C for 100 hours at 6VDC. Test after exposure to room
conditions for 2 hours.
Hold in chamber with 1000ppm sulfur density for 24 hours. Test after exposure
to room conditions for 2 hours.
Filter shall be preheated at 150 ± 20°C for 60 seconds, immersed whole
electrode in soldering bath at 240 ± 5°C for 3 ± 1 seconds, then measured after
exposure to room conditions for 2 hours.
Lead terminals are immersed up to 1.5mm from package base in soldering bath
at 260 ± 5°C for 10 ± 1 seconds, then measured after exposure to room
conditions for 2 hours.
TEST METHOD
MIL-STD-202E
Method 101D
MIL-STD-202E
Method 102A
MIL-STD-202E
Method 103B
MIL-STD-202E
MIL-STD-202E
Method 107D
MIL-STD-202E
Method 108A
MIL-STD-202E
Method 108A
MIL-STD-202E
Method 210A
ELECTRICAL
TEST ITEM
Dielectric Withstanding
Voltage
Insulation Resistance
Temperature
Characteristics
PACKAGE
BOTH
BOTH
SMD
LEADED
TEST CONDITIONS
Apply 100VDC between I/O terminals and ground terminal, for 1 minute.
Apply 100VDC between I/O terminals and ground terminal, for 1 minute.
Filter shall be measured between –10°C to +60°C temperature range.
Filter shall be measured between –10°C to +50°C temperature range.
TEST METHOD
MIL-STD-202E
MIL-STD-202E
Method 302
354 CG01-I

5 Page










PáginasTotal 5 Páginas
PDF Descargar[ Datasheet SAFC315MF70T.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
SAFC315MF70TCERAMIC MICROWAVE FILTERS SAW FILTERSMurata Manufacturing
Murata Manufacturing

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar