DataSheet.es    


PDF VF7-11F11 Data sheet ( Hoja de datos )

Número de pieza VF7-11F11
Descripción Plug In Relays
Fabricantes Tyco 
Logotipo Tyco Logotipo



Hay una vista previa y un enlace de descarga de VF7-11F11 (archivo pdf) en la parte inferior de esta página.


Total 7 Páginas

No Preview Available ! VF7-11F11 Hoja de datos, Descripción, Manual

www.DataSheet4U.com
Plug-in relays
Mini ISO relays
Power relay F7 / VF7
Features
– Limiting continuous
current 70 A
– Dimensional characteristics
and the functional allocation
of the plug-in terminals to
ISO 7588
– Standardized dimensions
– 24 V versions with contact
gap > 0.8 mm on request
- Plug-in or PCB terminals
Typical applications
– Rear window defogger
– Battery disconnection
– Power distribution (clamp 15)
Powertrain
Systems
Chassis
Systems
Safety
Security
Body
Driver
Convenience
Information
Car Industry
Truck
Industry
Design
Dustproof;
protection class IP 54 to IEC 529
(EN 60 529);
with either mounting bracket or
mounting clip
Weight
Approx. 1.3 oz. (38 g)
Nominal voltage
6 V, 12 V or 24 V;
other nominal voltages available
on request
Terminals
Quick connect terminals similar to ISO
8092-1
coil 6.3 x 0.8 mm,
load 9.5 x 1.2 mm;
surfaces tin-plated
or
PCB terminals
Accessories
Connectors see page 519
Special models on request
– Integrated components: resistor,
varistor, diode
– Special labels
– Special cover shapes
Conditions
All parametric, environmental and
endurance tests are performed
according to EIA Standard RS-407-A
at standard test conditions unless
otherwise noted:
23 °C ambient temperature,
20-50% RH, 29.5 ± 1.0" Hg
(998.9 ±33.9 hPa).
134_kop2
Other
Industry
392
All specifications subject to change. Consult Tyco Electronics AMP GmbH for latest specifications.

1 page




VF7-11F11 pdf
www.DataSheet4U.com
Plug-in relays
Mini ISO relays
Power relay F7 / VF7
Coil data
Available for nominal voltages
Nominal coil resistance
Resistor parallel to coil1)
Nominal power consumption
Test voltage winding/contact and contact/contact
Ambient temperature range 2)
Upper limit temperature for the coil
Max. switching rate without current
Operate time3)
Release time4)
6 VDC
Power F7
18
- / 180
2.0/2.2 W
12 VDC
Power VF7
91
-
1.6 W
24 VDC
Power VF7
Power F7
Power VF7
72
332
288
-/680
- -/2700
2.0/2.2 W
1.7 W
2.0/2.2 W
500 VACrms
– 40 to + 125 °C
180 °C
20 Hz
Typ. 7 msec
Typ. 2 msec
1) Power relay VF7 available with and without resistor (see ordering information), parallel devices on power relay F7 on request
2) See also operating voltage range diagramm and temperature vs. coil voltage for continuous load diagram
3) Measured at nominal voltage without coil suppression device
4) Measured with zero V applied (for unsuppressed relays after having been energized at nominal coil voltage)
N.B.
A low resistive device in parallel to the relay coil slows down the armature movement
and reduces the lifetime caused by increased erosion and/or higher risk of contact tack welding.
Operating voltage range
Does not take into account
the temperature rise due to
the contact current
E = pre-energization
Ambient temperature vs. coil
voltage for continuous duty
Battery voltage
130
134J_atcv
120
110
100
90
80
70
60
50
40 0 A Contact Load
14 A Contact Load
28 A Contact Load
30 42 A Contact Load
56 A Contact Load
20
70 A Contact Load
10
90 95 100 105 110 115 120 125 130 135 140 145 150
Applied Coil Voltage (% of Nominal Voltage)
Assumptions:
1. Still air
2. Nominal coil resistance
3. Maximum mean coil temperature = 180 °C
4. Coil temperature rise due to load = 2 °C at 14 A
= 4 °C at 28 A
= 26 °C at 42 A
= 40 °C at 56 A
= 78 °C at 70 A
5. Thermal resistance and power dissipation based on
coil resistance at 180 °C
6. Curves are based on 1.6 W at 23 °C
7. When full lifetime is at high ambient and high load
current, subtract 25 °C from maximum allowable
ambient temperature.
Mechanical data
Cover retention
Dust cover (force axially applied)
Pull
Push
Terminals
Pull force
Push force
Resistance to bending, force applied to front
Resistance to bending, force applied to side
Torsion
Enclosures
Dust cover
150 N (33.7 lbs)
200 N (45 lbs)
200 N (45 lbs)
100 N (22.5 lbs)
100 N (22.5 lbs)
10 N (2.25 lbs)1)
10 N (2.25 lbs)1)
0.3 Nm
Protects relay from dust. For use in passenger compartment or enclosures.
1) Values apply 2 mm from the end of the terminal. When the force is removed, the terminal must not have moved by more than 0.3 mm.
396
All specifications subject to change. Consult Tyco Electronics AMP GmbH for latest specifications.

5 Page










PáginasTotal 7 Páginas
PDF Descargar[ Datasheet VF7-11F11.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
VF7-11F11Plug In RelaysTyco
Tyco
VF7-11F12Plug In RelaysTyco
Tyco

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar