DataSheet.es    


PDF 945-F4Y-2D-00x Data sheet ( Hoja de datos )

Número de pieza 945-F4Y-2D-00x
Descripción Ultrasonic Sensors
Fabricantes ETC 
Logotipo ETC Logotipo



Hay una vista previa y un enlace de descarga de 945-F4Y-2D-00x (archivo pdf) en la parte inferior de esta página.


Total 30 Páginas

No Preview Available ! 945-F4Y-2D-00x Hoja de datos, Descripción, Manual

Ultrasonic Sensors
Compact 18 mm Diameter Digital
940 Series
FEATURES
ɀ Sensing distance up to 1,5 meters
ɀ 18 mm diameter housing
ɀ IP 67 sealing
ɀ High output current
ORDER GUIDE
Sensor
Package
Style
Sensing
Range*
mm (in.)
Digital
Output
18 mm dia.
200 - 1500
PNP, N.O.
PBTB Plastic
(7.87 - 59.05)
NPN, N.O.
PNP, N.O.
NPN, N.O.
150 - 700
PNP, N.O.
(5.9 - 27.5)
NPN, N.O.
PNP, N.O.
NPN, N.O.
* Standard target is 120 mm square of mild steel perpendicular to ultrasonic beam.
Termination
Cable
Cable
Connector cable
Connector cable
Cable
Cable
Connector cable
Connector cable
ɀ High power transducer
ɀ Microprocessor controlled
Catalog
Listing
940-F4Y-2D-001-180E
940-F4Y-2D-002-180E
940-F4X-2D-001-180E
940-F4X-2D-002-180E
940-F4Y-2D-001-300E
940-F4Y-2D-002-300E
940-F4X-2D-001-300E
940-F4X-2D-002-300E
SPECIFICATIONS
wwwC.aDtaalotgaLSishtiengest4U.com994400--FF44YY--22DD--000012--118800EE
940-F4X-2D-001-180E
940-F4X-2D-002-180E
940-F4Y-2D-001-300E
940-F4Y-2D-002-300E
940-F4X-2D-001-300E
940-F4X-2D-002-300E
Max. Sensing Distance
1500 mm (59.05 in.)
700 mm (27.5 in.)
Min. Sensing Distance
200 mm (7.87 in.)
150 mm (5.91 in.)
Beam Angle
8°
8°
POWER SUPPLY
Supply Voltage
19 - 30 VDC
Supply Current
<25 mA without load
<35 mA without load
Circuit Protection
Reverse polarity
OUTPUT CHARACTERISTICS
Load Current
0 - 500 mA
Switching Frequency
8 Hz
25 Hz
Hysteresis
2% of setpoint
2.5% of setpoint
Repeatability
± 1 mm
Setpoint Adjustment
4-turn potentiometer
Circuit Protection
Short circuit
ENVIRONMENTAL
Operating Temperature
– 15 to 70°C (5 to 158°F)
Storage Temperature
– 25 to 85°C (– 13 to 185°F)
Sealing
IP 67
SPECIAL FEATURES
Hold Input
Stops transmission and reception when input is connected to 0 VDC. Last output will be stored until input is disconnected
Synchronization Input
Avoids mutual interference from several sensors by interconnecting the hold input from each sensor.
LED Indicator
Illuminates when sensor detects target
B82 Honeywell ɀ MICRO SWITCH Sensing and Control ɀ 1-800-537-6945 USA ɀ ⍣1-815-235-6847 International ɀ 1-800-737-3360 Canada
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

1 page




945-F4Y-2D-00x pdf
Ultrasonic Sensors
942 Series
Compact 30 mm Diameter Analog and Digital, RS232/RS485 Interface
FEATURES
ɀ Programmable
ɀ RS232 or RS485 interface
ɀ 0 - 10 VDC/4 - 20 mA output
ɀ Two N.O. PNP outputs or one N.O.
PNP/one N.C. PNP output
ORDER GUIDE
Sensor
Package
Style
Sensing
Range*
mm (in.)
Analog
Output
Digital
Output
30 mm dia.
300 - 3000
0 - 10 V
PNP, N.O./N.C.
Stainless Steel
(11.8 - 118)
4 - 20 mA
PNP, N.O./N.C.
0 - 10 V
PNP, N.O./N.C.
4 - 20 mA
PNP, N.O./N.C.
150 - 1500
0 - 10 V
PNP, N.O./N.C.
(5.9 - 59.1)
4 - 20 mA
PNP, N.O./N.C.
0 - 10 V
PNP, N.O./N.C.
4 - 20 mA
PNP, N.O./N.C.
272,1g (9.6 oz)
100 - 600
(3.94 - 23.6)
0 - 10 V
PNP, N.O./N.C.
* Standard target is 120 mm square of mild steel perpendicular to ultrasonic beam.
www.DataSheet4U.com
SPECIFICATIONS
Interface
RS232
RS232
RS485
RS485
RS232
RS232
RS485
RS485
RS232
Catalog
Listing
942-A4N-2D-1C1-130E
942-A4N-2D-1D1-130E
942-A4N-2D-1E1-130E
942-A4N-2D-1F1-130E
942-A4N-2D-1C1-220S
942-A4N-2D-1D1-220S
942-A4N-2D-1E1-220S
942-A4N-2D-1F1-220S
942-A4N-2D-1C1-300E
Catalog Listings
942-A4N-2D-1C1-130E
942-A4N-2D-1D1-130E
942-A4N-2D-1E1-130E
942-A4N-2D-1F1-130E
942-A4N-2D-1C1-220S
942-A4N-2D-1D1-220S
942-A4N-2D-1E1-220S
942-A4N-2D-1F1-220S
942-A4N-2D-1C1-300E
Max. Sensing Distance
3000 mm (118 in.)
1500 mm (59.1 in.)
600 mm (23.6 in.)
Min. Sensing Distance
300 mm (11.8 in.)
150 mm (5.91 in.)
100 mm (3.94 in.)
Beam Angle
8°
10° 8°
POWER SUPPLY
Supply Voltage
19 - 30 VDC
Supply Current
< 30 mA without load
Circuit Protection
Reverse Polarity
OUTPUT CHARACTERISTICS (DIGITAL)
Load Current
0 - 100 mA
Hysteresis
Programmable (0 - 255 mm)
Switching Frequency
Programmable 5-30 Hz
Programmable 5-30 Hz
Programmable 5-50 Hz
Repeatability
±2 mm or ±0.4% of reading
Setpoint Adjust
Programmable within sensing range
Circuit Protection
Short circuit
OUTPUT CHARACTERISTICS (ANALOG)
Switching Frequency
Programmable 5-30 Hz
Programmable 5-30 Hz
Programmable 5-50 Hz
Repeatability
±2 mm or ±0.4% of reading
Linearity
3 mm or ±0.5%
Output Adjust
Programmable
Circuit Protection
Short circuit
ENVIRONMENTAL
Operating Temperature
– 15 to 70°C (5 to 150°F
Storage Temperature
– 25 to 85°C (– 13 to 185°F)
Sealing
IP 65
SPECIAL FEATURES
Hold Input
Stops transmission and reception when input is connected to 0 VDC. Analog output would be zero.
Synchronization input
Avoids mutual interference from several sensors by interconnecting the Hold input from each sensor.
LED Indicator
Illuminates when sensor detects target
Programmable Parameters
Analog Output: Span, Offset, Positive or Negative slope
Digital Output: Hysteresis, N.O./N.C.
B86 Honeywell ɀ MICRO SWITCH Sensing and Control ɀ 1-800-537-6945 USA ɀ ⍣1-815-235-6847 International ɀ 1-800-737-3360 Canada
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

5 Page





945-F4Y-2D-00x arduino
Ultrasonic Sensors
Precision Digital 18 mm Diameter
FEATURES
ɀ Background suppression
ɀ Sealed to IP 65
ɀ Fixed or adjustable setpoint control
ORDER GUIDE
Sensor
Package
Style
18 mm dia.
Plastic
90,7 g (3.2 oz.)
18 mm dia.
Stainless Steel
www.DataSheet4U.com
Sensing
Range*
mm (in.)
100 - 500
(3.9 - 19.68)
100 - 200
(3.9 - 7.87)
200 - 500
(7.87 - 19.68)
70 - 180
(2.76 - 7.09)
100 - 500
(3.9 - 19.68)
100 - 200
(3.9 - 7.87)
ɀ Temperature compensation over 0 to
50°C (32 to 122°F)
ɀ Inhibit/synchronization input
ɀ Stainless steel or plastic housings
Setpoint
Fixed @ 400 mm (15.75 in.) ± 20 mm**
Fixed @ 200 mm (7.87 in.) ± 20 mm**
Setpoint adjustment within sensing range
Setpoint adjustment within sensing range
Setpoint adjustment within sensing range
Setpoint adjustment within sensing range
Output
Type
PNP, N.O.
NPN, N.O.
PNP, N.O.
NPN, N.O.
PNP, N.O.
PNP, N.O.
PNP, N.O.
NPN, N.O.
PNP, N.O.
NPN, N.O.
945 Series
Catalog
Listing
945-F4Y-AD-001
945-F4Y-AD-002
945-N4Y-AD-001
945-N4Y-AD-002
945-F4Y-AD-001-180E
945-F4Y-AD-001-300E
945-L4Y-AD-001
945-L4Y-AD-002
945-S4Y-AD-001
945-S4Y-AD-002
136 g (4.8 oz.)
* Standard target is 120 mm square of mild steel perpendicular to ultrasonic beam.
**External setpoint adjustment wiring possible.
SPECIFICATIONS
SENSING CHARACTERISTICS
Catalog Listings
945-F4Y-AD-001
945-F4Y-AD-002
945-L4Y-AD-001
945-L4Y-AD-002
945-N4Y-AD-001
945-N4Y-AD-002
945-S4Y-AD-001
945-S4Y-AD-002
945-F4Y-AD-001-180E
945-F4Y-AD-001-300E
Max. Sensing Distance
500 mm (19.66 in.)
200 mm (7.87 in.)
500 mm (19.66 in.)
180 mm (7.09 in.)
Min. Sensing Distance
100 mm (3.9 in.)
100 mm (3.9 in.)
200 mm (7.87 in.)
70 mm (2.76 in.)
Beam Angle
10°
10°
8°
8°
POWER SUPPLY
Supply Voltage
19 - 30 VDC
Supply Current
<30 mA without load
<25 mA without load
Circuit Protection
Reverse polarity
OUTPUT CHARACTERISTICS
Load Current
0 - 100 mA
Hysteresis
10 mm
Switching Frequency
30 Hz
60 Hz
25 Hz
60 Hz
Repeatability
± 0.5 mm or 0.3% or reading
±0.2 mm or 0.2% or reading
Setpoint Adjustment
(Fixed or External Circuit) or 4 Turn Potentiometer
Circuit Protection
Short Circuit
ENVIRONMENTAL
Operating Temperature
0 to 50°C (32 to 122°F)
Storage Temperature
0 to 70°C (32 to 150°F)
Sealing
IP 65
SPECIAL FEATURES
Hold Input
Stops transmission and reception when input is connected to 0 VDC. Last output will be stored until input is disconnected
Synchronization Input
Avoids mutual interference from several sensors. (External synchronization unit is required. See Accessories)
LED Indicator
Illuminates when sensor detects target
B90 Honeywell ɀ MICRO SWITCH Sensing and Control ɀ 1-800-537-6945 USA ɀ ⍣1-815-235-6847 International ɀ 1-800-737-3360 Canada
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

11 Page







PáginasTotal 30 Páginas
PDF Descargar[ Datasheet 945-F4Y-2D-00x.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
945-F4Y-2D-00xUltrasonic SensorsETC
ETC

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar