TSX Premium
www.DataSheet4U.com TSX RKY/TSX PSY
Racks/Power Supplies
Racks/Versorgungen
Racks/Alimentations
Bastidores/Alimentaciones
Rack/Alimentazioni
Quick Reference Guide
Kurzanleitung
Instruction de service
Guía de referencias rápidas
Guida di riferimento rapido

1 page




RKY pdf
General safety advice for users
• If the device is permanently connected, its electrical installation must include a device to isolate
it from twhewpoww.eDr sautpaplSy ahnedea ct4ircUui.t-cboremaker to protect it against overcurrents and isolation faults.
If this is not the case, the power socket must be grounded and be easily accessed. The device must
beconnectedtotheprotectiveground.
• If the device is supplied with 24 or 48 VDC, the low voltage circuits must be protected. Only use
power supplies which conform to the standards currently in force.
• Check that the supply voltages remain within the tolerance ranges defined in the technical
characteristics of the devices.
• Allmeasuresmustbetakentoensurethatanypowerreturn(immediate,warmorcold)doesnotlead
to a dangerous state which may place personnel or the installation at risk.
• Emergency stop devices must remain effective in all the device's operating mods, even those
which are abnormal (for example, when a wire becomes disconnected). Resetting these devices
must not cause uncontrolled or improper restarts.
• Cables which carry signals must be located where they do not cause interference with the control
system functions by capacitive, inductive or electromagnetic interference.
• Control system equipment and their control devices must be installed in such a way as to ensure
that they are protected against unintentional operation.
• Appropriatesafetymeasuresmustbetakenfortheinputsandoutputs,topreventimproperstates
in the control system device, if no signal is received.
6Equipmentoperation
The operational safety and availability of a device is its ability to avoid the appearance of faults and
to minimize their effects if they occur.
A fault inside the control system is known as :
• passive, if it results in an open output circuit (no command is sent to the actuators).
• active, if it results in a closed output circuit (a command is sent to the actuators).
From the safety point of view, a given fault is dangerous or not depending on the type of command
given during normal operation. A passive fault is dangerous if the normal command is the operation
of an alarm. An active fault is dangerous if it maintains or activates an undesirable command.
The system designer mustuse devices external to the PLCto protect against active faults inside
the PLC, whether they are indicated or not.
7Electricalandthermalcharacteristics
Details of the electrical and thermal characteristics of devices are given in the associated technical
documents (installation manuals, service instructions).
8Maintenance
Troubleshootingprocedure
• Control system equipment should only be repaired by qualified personnel (after sales service
engineer, or technician approved by Schneider Automation). Only certified replacement parts
or components should be used.
•Beforeperforminganyoperationonequipment,alwaysdisconnectthepowersupplyandmechanically
lock any moving parts.
Replacementandrecyclingofusedbatteries
Use batteries of the same type as the originals and dispose of defective batteries in the same way
as toxic waste.
3

5 Page





RKY arduino
TSX RKY•• standard racks and TSX RKY••E extendable racks
Installing modules
• Onaswtanwdward.DoraextateSndhaebleetr4acUkw.citohmaddress0
The rack with addresses 0 must hold a power supply module and the processor module. Since TSX
Premium PLCs can have two types of power supply (standard format or double format), the position
of the processor will depend on the type of power supply being used.
Usingastandardformatpowersupplymodule:
- the power supply module always occupies
position PS,
- the processor module must be installed in
position 00,
- the other modules should be installed from
position 01 onwards.
PS 00 01 02 03 04 05 06
Usingadoubleformatpowersupplymodule:
- the power supply module always occupies
positions PS and 00,
- the processor module must be installed in
position 01.
- the other modules should be installed from
position 02 onwards.
PS 00 01 02 03 04 05 06
• Onanextendablerackwithaddresses1to7
Each rack must have a power supply module, whether standard or double format.
Usingastandardformatpowersupplymodule:
- the power supply module always occupies
the position PS,
- the other modules should be installed from
position 01 onwards.
PS 00 01 02 03 04 05 06
Usingadoubleformatpowersupply:
- the power supply module always occupies
positions PS and 00,
- the other modules should be installed from
position 02 onwards.
PS 00 01 02 03 04 05 06
9

11 Page







PáginasTotal 28 Páginas
PDF Descargar[ Datasheet RKY.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
RK-0505SECONOLINE - DC/DC - CONVERTERRecom International Power
Recom International Power
RK-0509SECONOLINE - DC/DC - CONVERTERRecom International Power
Recom International Power
RK-051.8SECONOLINE - DC/DC - CONVERTERRecom International Power
Recom International Power
RK-0512SECONOLINE - DC/DC - CONVERTERRecom International Power
Recom International Power

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar