Número de pieza | XR16V2651 | |
Descripción | HIGH PERFORMANCE DUART | |
Fabricantes | Exar Corporation | |
Logotipo | ||
Hay una vista previa y un enlace de descarga de XR16V2651 (archivo pdf) en la parte inferior de esta página. Total 30 Páginas | ||
No Preview Available ! www.DataSheet4U.com
PRELIMINARY
XR16V2651
HIGH PERFORMANCE DUART WITH 32-BYTE FIFO AND POWERSAVE
JUNE 2006
REV. P1.0.0
GENERAL DESCRIPTION
The XR16V26511 (V2651) is a high performance dual
universal asynchronous receiver and transmitter
(UART) with 32 byte TX and RX FIFOs. The device
operates from 2.25 to 3.6 volts with 5 Volt tolerant
inputs and is pin-to-pin and software compatible to
Exar’s XR16V2551 and XR16L2551. The device
includes 2 additional capabilities over the
XR16V2650: Intel and Motorola data bus selection
and a “PowerSave” mode to further reduce sleep
current to a minimum during sleep mode. It supports
the Exar’s enhanced features of selectable FIFO
trigger level, automatic hardware (RTS/CTS) and
software flow control, and a complete modem
interface. An internal loopback capability allows
system diagnostics. Independent programmable
fractional baud rate generators are provided in each
channel to select data rates up to 16 Mbps at 3.3 Volt
and 4X sampling clock. The V2651 is available in 48-
pin TQFP and 32-pin QFN packages.
NOTE: 1 Covered by U.S. Patent #5,649,122
APPLICATIONS
• Portable Appliances
• Telecommunication Network Routers
• Ethernet Network Routers
• Cellular Data Devices
• Factory Automation and Process Controls
FEATURES
• 2.25 to 3.6 Volt Operation
• 5 Volt Tolerant Inputs
• Pin-to-pin compatible to Exar’s XR16L2751 in the
48-TQFP package
• Two independent UART channels
■ Register set identical to 16V2650
■ Data rate of up to 16 Mbps at 3.3 V, and 12.5
Mbps at 2.5 V with 4X sampling rate
■ Fractional Baud Rate Generator
■ Transmit and Receive FIFOs of 32 bytes
■ Selectable TX and RX FIFO Trigger Levels
■ Automatic Hardware (RTS/CTS) Flow Control
■ Automatic Software (Xon/Xoff) Flow Control
■ Wireless Infrared (IrDA 1.0) Encoder/Decoder
■ Automatic sleep mode with wake-up interrupt
■ Full modem interface
• PowerSave Feature reduces sleep current to 15 µA
• Device Identification and Revision
• Crystal oscillator (up to 32MHz) or external clock
(up to 64MHz) input
• 48-TQFP and 32-QFN packages
FIGURE 1. XR16V2651 BLOCK DIAGRAM
PwrSave
A2:A0
D7:D0
IOR# (VCC)
IOW# (R/W#)
CSA# (CS#)
CSB# (A3)
INTA (IRQ#)
INTB (logic 0)
TXRDYA#
TXRDYB#
RXRDYA#
RXRDYB#
Reset (Reset#)
16/68#
CLKSEL
Intel or
Motorola
Data Bus
Interface
*5 Volt Tolerant Inputs
UART Channel A
UART
Regs
BRG
32 Byte TX FIFO
TX & RX
IR
ENDEC
32 Byte RX FIFO
UART Channel B
(same as Channel A)
Crystal Osc/Buffer
2.25 to 3.6V VCC
GND
TXA, RXA, DTRA#,
DSRA#, RTSA#,
DTSA#, CDA#, RIA#,
OP2A#
TXB, RXB, DTRB#,
DSRB#, RTSB#,
CTSB#, CDB#, RIB#,
OP2B#
XTAL1
XTAL2
Exar Corporation 48720 Kato Road, Fremont CA, 94538 • (510) 668-7000 • FAX (510) 668-7017 • www.exar.com
1 page REV. P1.0.0
Pin Description
PRELIMINARY
XR16V2651
HIGH PERFORMANCE DUART WITH 32-BYTE FIFO AND POWERSAVE FEATURE
NAME
OP2A#
TXB
RXB
RTSB#
CTSB#
DTRB#
DSRB#
CDB#
RIB#
OP2B#
32-QFN 48-TQFP
TYPE
PIN # PIN #
DESCRIPTION
- 32 O Output Port 2 Channel A - The output state is defined by the user and through the
software setting of MCR[3]. INTA is set to the active mode and OP2A# output LOW
when MCR[3] is set to a logic 1. INTA is set to the three state mode and OP2A#
output HIGH when MCR[3] is set to a logic 0. See MCR[3]. If INTA is used, this out-
put should not be used as a general output else it will disturb the INTA output func-
tionality.
6 8 O UART channel B Transmit Data or infrared encoder data. Standard transmit and
receive interface is enabled when MCR[6] = 0. In this mode, the TX signal will be
HIGH during reset or idle (no data). Infrared IrDA transmit and receive interface is
enabled when MCR[6] = 1. In the Infrared mode, the inactive state (no data) for the
Infrared encoder/decoder interface is LOW. If it is not used, leave it unconnected.
3 4 I UART channel B Receive Data or infrared receive data. Normal receive data input
must idle HIGH. The infrared receiver pulses typically idles at logic 0 but can be
inverted by software control prior going in to the decoder, see MCR[6]. If this pin is
not used, tie it to VCC or pull it high via a 100k ohm resistor.
15 22 O UART channel B Request-to-Send (active low) or general purpose output. This port
must be asserted prior to using auto RTS flow control, see EFR[6], MCR[1], and
IER[6].
16 23 I UART channel B Clear-to-Send (active low) or general purpose input. It can be
used for auto CTS flow control, see EFR[7], and IER[7]. This input should be con-
nected to VCC when not used.
- 35 O UART channel B Data-Terminal-Ready (active low) or general purpose output. If it
is not used, leave it unconnected.
- 20 I UART channel B Data-Set-Ready (active low) or general purpose input. This input
should be connected to VCC when not used. This input has no effect on the UART.
- 16 I UART channel B Carrier-Detect (active low) or general purpose input. This input
should be connected to VCC when not used. This input has no effect on the UART.
- 21 I UART channel B Ring-Indicator (active low) or general purpose input. This input
should be connected to VCC when not used. This input has no effect on the UART.
- 9 O Output Port 2 Channel B - The output state is defined by the user and through the
software setting of MCR[3]. INTB is set to the active mode and OP2B# output LOW
when MCR[3] is set to a logic 1. INTB is set to the three state mode and OP2B#
output HIGH when MCR[3] is set to a logic 0. See MCR[3]. If INTB is used, this out-
put should not be used as a general output else it will disturb the INTB output func-
tionality.
ANCILLARY SIGNALS
XTAL1
10
13
XTAL2
11
14
I Crystal or external clock input.
O Crystal or buffered clock output.
PwrSave 9
12 I PowerSave (active high). This feature isolates the V2651’s data bus interface from
the host preventing other bus activities that cause higher power drain during sleep
mode. See Sleep Mode with Auto Wake-up and PowerSave Feature section for
details.
5
5 Page PRELIMINARY
XR16V2651
REV. P1.0.0
HIGH PERFORMANCE DUART WITH 32-BYTE FIFO AND POWERSAVE FEATURE
2.8 Crystal Oscillator or External Clock Input
The V2651 includes an on-chip oscillator (XTAL1 and XTAL2) to produce a clock for both UART sections in the
device. The CPU data bus does not require this clock for bus operation. The crystal oscillator provides a
system clock to the Baud Rate Generators (BRG) section found in each of the UART. XTAL1 is the input to the
oscillator or external clock buffer input with XTAL2 pin being the output. For programming details, see
““Section 2.9, Programmable Baud Rate Generator with Fractional Divisor” on page 11.”
FIGURE 4. TYPICAL CRYSTAL CONNECTIONS
XTAL1
C1
22-47pF
XTAL2
R2
500K - 1M
R1
0-120
(Optional)
Y1
1.8432 MHz
to
24 MHz
C2
22-47pF
The on-chip oscillator is designed to use an industry standard microprocessor crystal (parallel resonant,
fundamental frequency with 10-22 pF capacitance load, ESR of 20-120 ohms and 100 ppm frequency
tolerance) connected externally between the XTAL1 and XTAL2 pins (see Figure 4). The programmable Baud
Rate Generator is capable of operating with a crystal oscillator frequency of up to 24 MHz. However, with an
external clock input on XTAL1 pin, it can extend its operation up to 64 MHz (16 Mbps serial data rate) at 3.3V
with an 4X sampling rate. For further reading on the oscillator circuit please see the Application Note DAN108
on the EXAR web site at http://www.exar.com.
2.9 Programmable Baud Rate Generator with Fractional Divisor
Each UART has its own Baud Rate Generator (BRG) with a prescaler for the transmitter and receiver. The
prescaler is controlled by a software bit in the MCR register. The MCR register bit-7 sets the prescaler to divide
the input crystal or external clock by 1 or 4. The output of the prescaler clocks to the BRG. The BRG further
divides this clock by a programmable divisor between 1 and (216 - 0.0625) in increments of 0.0625 (1/16) to
obtain a 16X or 8X or 4X sampling clock of the serial data rate. The sampling clock is used by the transmitter
for data bit shifting and receiver for data sampling. The BRG divisor (DLL, DLM and DLD registers) defaults to
the value of ’1’ (DLL = 0x01, DLM = 0x00 and DLD = 0x00) upon reset. Therefore, the BRG must be
programmed during initialization to the operating data rate. The DLL and DLM registers provide the integer part
of the divisor and the DLD register provides the fractional part of the dvisior. Only the four lower bits of the DLD
are implemented and they are used to select a value from 0 (for setting 0000) to 0.9375 or 15/16 (for setting
1111). Programming the Baud Rate Generator Registers DLL, DLM and DLD provides the capability for
selecting the operating data rate. Table 6 shows the standard data rates available with a 24MHz crystal or
external clock at 16X clock rate. If the pre-scaler is used (MCR bit-7 = 1), the output data rate will be 4 times
less than that shown in Table 6. At 8X sampling rate, these data rates would double and at 4X sampling rate,
they would quadruple. Also, when using 8X or 4X sampling mode, please note that the bit-time will have a jitter
11
11 Page |
Páginas | Total 30 Páginas | |
PDF Descargar | [ Datasheet XR16V2651.PDF ] |
Número de pieza | Descripción | Fabricantes |
XR16V2650 | HIGH PERFORMANCE DUART | Exar Corporation |
XR16V2651 | HIGH PERFORMANCE DUART | Exar Corporation |
XR16V2652 | HIGH PERFORMANCE DUART | Exar Corporation |
Número de pieza | Descripción | Fabricantes |
SLA6805M | High Voltage 3 phase Motor Driver IC. |
Sanken |
SDC1742 | 12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters. |
Analog Devices |
DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares, |
DataSheet.es | 2020 | Privacy Policy | Contacto | Buscar |