No Preview Available ! DK-B10 Hoja de datos, Descripción, Manual

DC Current transducer DK-B5/10
A split core transducer for the electronic measurement DC current,
with galvanic isolation between the primary (High power) and the
secondary circuits (Electronic circuit) with voltage output.
I = 50..400 A
PN
Electrical data
Primary Nominal Current
I (A.t)
PN
Analogue Output Signal 1) Type
V (V)
OUT
RoHs
Date Code
Features
V
www.DataSheet4U.com c
R
L
V
b
Vd
f
Ic
50,75,100
100,150,200
150,225,300
200,300,400
50,75,100
100,150,200
150,225,300
200,300,400
Supply voltage
0-5
0-5
0-5
0-5
0-10
0-10
0-10
0-10
Load resistance
Rated voltage (CAT III, PD2)
Isolation voltage
Frequency
Current consumption (max)
DK 100 B5
DK 200 B5
DK 300 B5
DK 400 B5
DK 100 B10
DK 200 B10
DK 300 B10
DK 400 B10
20-50
22-38
50 .. 250
150
3000
DC
100
planned
planned
planned
planned
MAY 2006
MAY 2006
planned
planned
V DC
V AC
k
V AC
V AC
mA
Accuracy - Dynamic performance data
DC Measurement
Split core box
Voltage output
Jumper selectable ranges
Panel mounting
Extended measuring range.
Advantages
Large aperture
High isolation between primary and
secondary circuits
Easy to mount
No insertion losses.
Applications
X Accuracy @ I , T =25°C
PN A
DK 300 BXX
±1
± 1.5
% Battery Banks
% - Monitors load current.
DK 400 BXX
εL Linearity error
tr Response time @ 90% of IPN
±2
± 0.75
< 300
% - Monitors charging current.
% - Verifies operation.
mS Transportation
Measures traction power or auxiliary
General data
TA Ambient operating temperature (0-95% RH)
TS Ambient storage temperature
m Mass
- 20 .. + 50
- 20 .. + 85
120
loads.
Electric Heating Elements
°C Faster response than temperature
°C sensors.
g
Protection type
Safety
IP 20
IEC 61010-1
Options on request
EMC
EN 61326 2)
DIN mounting.
Notes : 1) For 0-3 V output model, no saturation output up to 3.5 V for 0-5 V output
model, no saturation output up to 5.75 V and for 0-10 V output model, no
saturation output up to 11.5 V
2) For IEC 61000-4-3, IEC 61000-4-6 and IEC 61000-4-4 Criterion B :
temporary impairment to operational behavior.
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
060616/9
page 1/2
LEM
www.lem.com

1 page





PáginasTotal 2 Páginas
PDF Descargar[ Datasheet DK-B10.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
DK-B10(DK-B5/10) DC Current transducerLEM
LEM

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar