1” High Resolution Resistron® –
Camera Tube
XQ 1395
For use in medical TV application
Antimonytrisulfide – photoconductive layer (Sb2S3)
Separate mesh connection (grid-4-electrode)
Description
Camera Tubes are the key component of
High Performance X-ray TV systems in
medical applications. Their high
sensitivity and high dynamic range
combined with high resolution allows
real-time x-ray imaging for any type of
medical imaging as during critical
surgeries. The Resistron® camera tube
XQ 1395 is a 1” diameter image tube with
magnetic focusing and magnetic
deflection method for camera installations
adapted through optics to X-ray image
intensifiers.
Features and Benefits
High sensitivity
Video high-resolution
High dynamic range
Real-time X-ray imaging
Low noise imaging
Applications
Radiography
Cardiology
C-arm
Angiography
Radiosurgery
www.optoelectronics.perkinelmer.com

1 page




XQ1395 pdf
Blemish Specification
- Test Conditions
The tube shall be centred and focused according to the operating and adjusting instructions for
optimum performance.
Illumination should be adjusted to a signal current of 250 nA at a beam current for stabilising a
signal of 500 nA.
- Target Zone
A uniformly illuminated field with an aspect ratio of 3:4 and a scanned area of 15.0 mm x 20.0 mm
shall be displayed on the target of the camera tube. According to the following drawing the scanned
area is divided into three zones 1, 2 and 3.
The blemish size is measured in percent of the picture height. The equivalent numbers of TV-lines
are indicated for comparison purposes only. Black and white spots are equally weighted.
Measurement of blemishes will be performed with and without target illumination. The minimum
separation between two target spots must be greater than the diameter of the larger one, otherwise
the combination is considered as a whole. Target spots with a diameter 0.2 % of the picture height
as well as blemishes with a modulation depth 10 % are not counted, unless an accumulation
causes a smudged appearance.
Blurred spots, streaks, stripes, mesh defects and mottled or grainy background are only permitted
up to a noise amplitude of 10 %.
20 mm
Figure 2
Target Zone of Image Tubes
10 mm
5 mm
Zone 3
Zone 2
Zone 1
Possible Number, Size and Location of Blemishes
Specification
Blemish size in % of picture height Blemish size TV lines
15.0mm = 100 %
625 line system
> 0.7
>4
> 0.5 … 0.7
>3…4
> 0.2 … 0.5
>1…3
Max. permissible total number of blemishes
Maximum permissible number of blemishes
Zone 1
Zone 2
Zone 3
000
001
024
4
Blemishes outside the zone are not counted.
www.optoelectronics.perkinelmer.com
Camera Tube
5

5 Page










PáginasTotal 6 Páginas
PDF Descargar[ Datasheet XQ1395.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
XQ1395High Resolution ResistronPerkinElmer
PerkinElmer

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar