Terminator I/O Specifications
AC OUTPUT MODULES
T1K-08TA <--->
T1K-16TA <--->
8-point and 16-point,
AC output modules
The 8-point AC module uses a T1K-08B
or T1K-08B-1 base, which is purchased
separately.
The 16-point AC module uses a
T1K-16B or T1K-16B-1 base, which is
purchased separately.
Specifications
T1K-08TA
T1K-16TA
Outputs per Module
Commons per Module
Operating Voltage Range
Output Voltage Range
Max. Load Current
ON Voltage Drop
Max. Leakage Current
Max. Inrush Current
Min. Load
OFF to ON Response
ON to OFF Response
Base Power Required
Status Indicators
Error Status
Indications(LEDs )
Fuses (User Replaceable)
T1K-FUSE-1
Weight
8 16
2 (4 pts. / common) isolated
4 (4 pts. / common) isolated
17-240 VAC (47-63Hz) min./max.
15-264 VAC (47-63Hz) min./max.
1A / pt., 4A / common (subject to derating)
1.5VAC @ > 50mA, 4.0VAC @ < 50mA
4mA @ 264 VAC
10A for 10ms
10mA
< 1ms
< 1ms + 1/2 cycle
250mA @ 5VDC
450mA @ 5VDC
Logic side
FU1 ON = fuse 1 blown
FU2 ON = fuse 2 blown
FU1/FU2 ON = fuse 1 or 2 blown
FU3/FU4 ON = fuse 3 or 4 blown
2, (10A, 250V / common)
5 x 20 mm type
4, (10A, 250V / common)
5 x 20 mm type
140g 190g
Equivalent Output Circuit
www.DataSheet4U.com
w w w. a u t o m a t i o n d i r e c t . c o m / f i e l d I O
Universal Field I/O 7–41

1 page




T1K-16TA pdf
Terminator I/O Specifications
EXPANSION I/O CONFIGURATIONS
Expansion cables
T1K-10CBL
<--->
T1K-10CBL-1*
<--->
Right side to left side
expansion cable
The T1K-10CBL(-1) connects the right
side of an I/O base to the left side of the
next I/O base. A maximum of two
T1K-10CBL(-1) cables can be used per
expansion system.
T1K-05CBL-LL
T1K-05CBL-LL-1*
Left side to left side
expansion cable
<--->
<--->
The T1K-05CBL-LL(-1) connects the left
side of an I/O base to the left side of the next
I/O base. Only one T1K-05CBL-LL(-1)
cable can be used per expansion system and
must be used with a T1K-05CBL-RR(-1)
cable. This cable cannot be connected to
the left side of the network interface base.
T1K-05CBL-RR
<--->
T1K-05CBL-RR-1* <--->
Right side to right side
expansion cable
The T1K-05CBL-RR(-1) connects the
right side of an I/O base to the right side
of the next I/O base. A maximum of one
T1K-05CBL-RR(-1) cable can be used
per expansion system. Note: When this
cable is used, the expansion I/O assign-
ments are from right to left (reversed).
Cable length = 1.0m
Cable length = 0.5m
Cable length = 0.5m
*Note: The (-1) versions of the expansion cables pass 24VDC through on an isolated wire. (All cables pass the 5VDC base power.)
Any local expansion DC input modules configured for “internal power” (current sourcing) must either have a power supply
preceding it on the same base or, have a (-1) version cable pass 24VDC from a power supply on the preceeding base.
Using two T1K-10CBL expansion cables
In the system below, power supplies can be used anywhere.
T1K-10CBL(-1)
I/O Addressing
T1K-10CBL(-1)
Using T1K-10CBL expansion cable
and T1K-05CBL-RR expansion cable
Power supplies can be used anywhere in the first two bases,
but not in the last expansion base.
A power supply can
be used on either base.
I/O Addressing
A power supply cannot be
used on a base that is
connected to a system by
aT1K-05CBL-RR(-1).
T1K-10CBL(-1)
T1K-05CBL-RR(-1)
See Note above
Using T1K-05CBL-RR expansion cable
and T1K-05CBL-LL expansion cable
Power supplies can be used anywhere in the first and third bases,
but not in the second base.
Using T1K-05CBL-RR expansion cable
Power supplies can be used anywhere in the first base, but not in the
second base
Do not connect a
T1K-05CBL-LL(-1)
to the left side of the
network interface base.
I/O Addressing
T1K-05CBL-RR(-1) See
Note above
I/O Addressing
T1K-05CBL-RR(-1)
See Note above
T1K-05CBL-LL
A power supply cannot be
used on a base that is
connected to a system by
a T1K-05CBL-RR(-1).
w w w. a u t o m a t i o n d i r e c t . c o m / f i e l d I O
A power supply cannot be
used on a base that is
connected to a system by
a T1K-05CBL-RR(-1).
Universal Field I/O 7–17

5 Page










PáginasTotal 6 Páginas
PDF Descargar[ Datasheet T1K-16TA.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
T1K-16TA(T1K16TA / T1K08TA) Discrete AC Output ModulesETC
ETC

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar