OCTOBER 1997
SURSENSEUltra Low Pressure Sensors
DCAL4 Series
Ratiometric 4-Volt Output
High Accuracy Compensation
Full Scale Pressure Ranges
0 to 1 in. H2O to 0 to 30 in. H2O
±0 to ±1 in. H2O to ±0 to ±30 in. H2O
DESCRIPTION
The SURSENSE™ line of ultra low pressure sensors is based
upon a proprietary, patent applied for technology designed
to reduce all output offset or common mode errors.
These sensors utilize a silicon, micromachined sensing element
which features a unique stress concentration enhanced
structure to provide a highly stable linear output that is
proportional to applied pressure. Output offset errors due to
changes in temperature, warm-up, long term stability and
position sensitivity have all been significantly reduced when
compared to conventional sensors.
The DCAL series sensors provide a precision calibrated
ratiometric 4 -volt output with SURSENSE enhanced stability.
Each sensor features the precision calibration found in the
DCX series with the addition of fully integrated signal
conditioning in an industry standard package. Intended to
operate from a fixed 5Vdc supply, the DCAL4 gage pressure
sensors provide a 0.25v to 4.25v output while the differential
versions provide a ±2.0 volt output centered on a 2.25 volt
zero pressure offset. These highly stable sensors are ideally
suited for microprocessor or microcontroller based systems.
APPLICATIONS
s Medical Instrumentation
s HVAC
s Environmental Controls
s Portable Monitors
FEATURES
s Available in Gage and Differential
Pressure Ranges
s Temperature Compensated over 0°C to 50°C
s Position Sensitivity to ±5mV/g
s Warm-up drift < ±5mV
s Long Term Stability < ±10mV
s Combined Linearity and Hysteresis Error
< ±0.25%FS
s Custom Calibration Available
EQUIVALENT CIRCUIT
+
VEXCITATION (1)
VOUTPUT (3)
VOFFSET (4)
Common (2)
PINOUT
1
2
3
4
VEXCITATION
Common
VOUTPUT
VOFFSET

1 page




DC005NDC4 pdf
DCAL405DN
Ratiometric 4-Volt Output
High Accuracy Compensation
±5 in. H2O Full Scale Pressure
DCAL Series
SURSENSEUltra Low Pressure Sensors
MAXIMUM RATINGS
PARAMETER
Operating Temperature Range
Storage Temperature
Proof Pressure
Burst Pressure
Output Source Current
Output Sink Current
Excitation Voltage
Common Mode Pressure
MINIMUM
–25
–40
150
300
MAXIMUM
85
125
UNITS
°C
°C
in. H2O
in. H2O
3 16
V
50 psig
ELECTRICAL SPECIFICATIONS
PARAMETER, note 1
Operating Range, differential pressure
Output Span, note 2
Offset Voltage
Temperature Effect on Offset (0°C–50°C), note 3
Combined Temperature Effect on Span (0°C–50°C),
note 3
Offset Warm-up shift, note 4
Offset Position Sensitivity (±1g)
Offset Long Term Drift (one year)
Combined Linearity and Hysteresis Error, note 5
MINIMUM
±1.90
2.15
NORMAL
±5.0
±2.0
2.25
+1
MAXIMUM
±2.10
2.35
±20
±1
±5
±5
±10
0.05 0.25
Note 1: Reference conditions (unless otherwise noted): Supply Voltage, VS = 5VDC, TA = 25°C, Common Mode Line Pressure = 0 psig.
Pressure measurements are with pressure applied to Port B.
Note 2: The voltage added to the offset voltage at full scale pressure. Nominally the output voltage range is 0.25 to 4.25 volts.
Note 3: Shift is relative to 25°C.
Note 4: Shift is within the first hour of excitation applied to the device.
Note 5: Measured at one-half full scale rated pressure using best straight line curve fit.
UNITS
in. H2O
V
V
mV
%Span
mV
mV
mV
%FS

5 Page





DC005NDC4 arduino
DCAL430DN
Ratiometric 4-Volt Output
High Accuracy Compensation
±30 in. H2O Full Scale Pressure
DCAL Series
SURSENSEUltra Low Pressure Sensors
MAXIMUM RATINGS
PARAMETER
Operating Temperature Range
Storage Temperature
Proof Pressure
Burst Pressure
Output Source Current
Output Sink Current
Excitation Voltage
Common Mode Pressure
MINIMUM
–25
–40
450
750
MAXIMUM
85
125
UNITS
°C
°C
in. H2O
in. H2O
3 16
V
50 psig
ELECTRICAL SPECIFICATIONS
PARAMETER, note 1
Operating Pressure Range, gage pressure
Output Span, note 2
Offset Voltage
Temperature Effect on Offset (0°C–50°C), note 3
Combined Temperature Effect on Span (0°C–50°C),
note 3
Offset Warm-up shift, note 4
Offset Position Sensitivity (±1g)
Offset Long Term Drift (one year)
Combined Linearity and Hysteresis Error, note 5
MINIMUM
±1.90
2.15
NORMAL
±30.0
±2.0
2.25
MAXIMUM
±2.1
2.35
±20
±1
±5
±1
±10
0.05 0.25
Note 1: Reference conditions (unless otherwise noted): Supply Voltage, VS = 5VDC, TA = 25°C, Common Mode Line Pressure = 0 psig.
Pressure measurements are with pressure applied to Port B.
Note 2: The voltage added to the offset voltage at full scale pressure. Nominally the output voltage range is 0.25 to 4.25 volts.
Note 3: Shift is relative to 25°C.
Note 4: Shift is within the first hour of excitation applied to the device.
Note 5: Measured at one-half full scale rated pressure using best straight line curve fit.
UNITS
in. H2O
V
V
mV
%Span
mV
mV
mV
%FS

11 Page







PáginasTotal 12 Páginas
PDF Descargar[ Datasheet DC005NDC4.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
DC005NDC4Ultra Low Pressure SensorsETC
ETC

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar