MAP140 SERIES
Power-One’s MAP140 series provides a full range of options and up
to 30 watts more power than comparable products in this industry
standard footprint. With a universal input from 85 to 264 VAC and
power densities up to 2.6 watts/inch3, the MAP140 meets the most
rigorous requirements of commercial, industrial, and datacom systems.
Rated for use in convection and forced air cooled (200 LFM)
applications, the MAP140 delivers dependable power with a Mean
Time Before Failure (MTBF) in excess of 180,000 hours. In addition
to UL, CSA, and TÜV regulatory compliance, the MAP140 displays
the CE Mark.
FEATURES
• Universal Input 85-264 VAC
• Input Transient & ESD Compliance to EN61000-4-2/-3/-4
• CE Marked to Low Voltage Directive
• Industry Standard Footprint: 7.00" x 4.30" x 1.80"
(177.8mm x 109.2mm x 45.7mm)
• Remote Sense and Overvoltage Protection
• Power Fail Signal Standard on MAP140-3000P, Optional
on MAP140-1012 and MAP140-1024
• Optional Overtemperature Protection, L-Bracket, and Cover.
SINGLE OUTPUT MODEL SELECTION CHART
MODEL
MAP140-1012
MAP140-1024
MAP140-1048
OUTPUT
VOLTAGE
12V/15V
24V/28V
48V
ADJUSTMENT
RANGE
11.0V to 16.0V
22.8V to 29.2V
45.6V to 54.0V
CONVECTION
COOLED CURRENT
9.2/7.3A (Note 2)
4.6/4A (Note 2)
2.3A
FORCED AIR
CURRENT (NOTE 3)
12.5A/10A (Note 2)
6.3A/5.4A (Note 2)
3.1A
LINE
REGULATION
0.1%
0.1%
0.1%
LOAD
REGULATION
0.5%
0.5%
0.5%
RIPPLE & NOISE
%p-p (NOTE 1)
1%
1%
1%
INITIAL SETTING
ACCURACY
11.97V to 12.03V
23.95V to 24.05V
47.9V to 48.1V
NOTES: 1) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth.
2) MAP140-1012 output currents are expressed as 12V/15V operation. MAP140-1024 output currents are expressed as 24V/28V operation.
3) With 200 LFM forced air cooling.
MULTIPLE OUTPUT MODEL SELECTION CHART – 80W CONVECTION COOLED, 140W FORCED AIR COOLED (200 LFM)
MODEL
MAP140-3000P
OUTPUT
VOLTAGE
+5V
+12V
-12V
ADJUSTMENT
RANGE
4.75 - 5.25V
Fixed
Fixed
OUTPUT
CURRENT (NOTE 1)
16A/25A
4A/9A PK
1A/1.5A PK
PEAK OUTPUT
CURRENT (NOTE 1)
20A/25A PK
4A/9A PK
1A/1.5A PK
LINE
REGULATION
0.2%
0.1%
0.1%
LOAD
REGULATION
1%
2%
2%
RIPPLE & NOISE
%p-p (NOTE 2)
1%
1%
1%
INITIAL SETTING
ACCURACY
5.09V to 5.11V
11.97V to 12.03V
-11.4V to -12.6V
NOTES: 1) Peak loads up to 140 Watts for 60 seconds or less are acceptable, (10% duty cycle max.). Peak power must not exceed 140 watts.
2) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth.
INPUT SPECIFICATIONS
PARAMETER
Input Voltage - AC
Input Frequency
Brown Out Protection
Hold-up Time
Input Current
Input Protection
Inrush Surge Current
CONDITIONS/DESCRIPTION
Continuous input range.
AC input.
Lowest AC input voltage that regulation is maintained with full rated loads.
Nominal AC input voltage (110 VAC)
110 watt load:
140 watt load:
85 VAC (140W load).
110 VAC (140W load).
Non-user serviceable internally located AC input line fuse.
Internally limited by thermistor. Vin = 264VAC (one cycle). 25°C.
Operating Frequency
Switching frequency of main transformer.
MIN
NOM
MAX UNITS
85 264 VAC
47 63 Hz
85 VAC
20
16
mS
2.5 ARMS
2.0
41 APK
22 kHz
NUCLEAR AND MEDICAL APPLICATIONS Power-One products are not authorized for use as critical components in life support systems, equipment used in hazardous environments,
or nuclear control systems without the express written consent of the President of Power-One, Inc.
TECHNICAL REVISIONS The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are
subject to change without notice.
Rev. 04/2000
1

1 page





PáginasTotal 3 Páginas
PDF Descargar[ Datasheet MAP140.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
MAP140Universal Input 85-264 VACPower-One
Power-One

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar