DataSheet.es    


PDF PBL385822SOS Data sheet ( Hoja de datos )

Número de pieza PBL385822SOS
Descripción Telephone Line interface circuit for DECT/ DAM/ CT Unisolated or Isolated
Fabricantes Ericsson 
Logotipo Ericsson Logotipo



Hay una vista previa y un enlace de descarga de PBL385822SOS (archivo pdf) en la parte inferior de esta página.


Total 9 Páginas

No Preview Available ! PBL385822SOS Hoja de datos, Descripción, Manual

DecPeBmLbe3r 81959892
PBL 38582
Telephone Line interface circuit for
DECT, DAM, CT
Unisolated or Isolated
Description
PBL 38582 is a monolithic bipolar integrated circuit for use as telephone line interface in
unisolated or isolated DECT and other cordless telephone residential base stations and
in analog / digital answering machines or as second line in an unisolated DECT telephone
base station.
Transmit and receive gains are set by external components. On / Off switchable gain,
related to line, regulation for different current feeds can be set by external resistors.
Typical current feeds as 48 V, 2 • 200 ohm, 48 V 2 • 400 ohm and 60 V 2 • 600 ohm can
be handled. Application dependent parameters such as line balance, impedance to the
line and frequency response are set by external components. Parameters are set
independently which results in an easy adoption for various market needs.
Key Features
• Minimum number of inexpensive
external components, 5 capacitors
and 4 resistors.
• Current range
5 - 130 mA(DIL),
5 - 100 mA(20-pin SO)
5 - 70 mA(16-pin SO) 385 82/2
• Operation voltage range
down to 2 V.
• Short start-up time.
RECEIVE
TRANSMIT
PBL 38582
18
1
Fast start - up
1 7 Limiter
Reference
DC
supply
6 32
+
1 5 5, 14,16 4
2
1
Figure 1. Functional diagram. DIP package.
Telephone
line
16-pin plastic SO
20-pin plastic SO
18-pin plastic DIP
1

1 page




PBL385822SOS pdf
PBL 385 82
Functional description
Design procedure; ref. to fig.4.
The design is made easier through that all
settable parameters are returned to gro-
und (-line), this feature differs it from bridge
type solutions.To set the parameters in the
following order will result in that the
interaction between the same is minimized.
1. Set the circuit impedance to the line,
either 600or complex. (R3 and C1). C1
should be big enough to give low
impedance compared with R3 in the
telephone speech frequency band.Too
large C1 will make the start-up slow. See
fig. 10.
2. Set the DC-characteristic that is
required in the PTT specification or in case
of a system telephone,in the PBX
specification (R6).There are also internal
circuit dependent requirements like supply
voltages etc.
3. Set the attac point where the line
length regulation ( if used ) is supposed to
cut in. Note that in some countries the line
length regulation is not allowed. In most
cases the end result is better and more
readily achieved by using the line length
regulation (line loss compensation) than
without.
4. Set the transmitter gain and
frequency response.
5. Set the receiver gain and frequency
response. See text how to limit the max.
swing.
6. Adjust the side tone balancing
network if used.The network in most cases
is just a coarse resistive divider to take
care of the first order of balancing. The fine
balancing is done by the DSP in the sys-
tem.
7. Set the RFI suppression
components in case necessary.
8. Circuit protection. Apart from any
other protection devices used in the de-
sign a good practice is to connect a 15V
1W zener diode across the circuit , from
pin 1 to -Line.
Impedance to the line
The AC- impedance to the line is
set by R3, C1 and C2. Fig.6. The circuits
relatively high parallel impedance will not
influence the line impedance to any
noticeable extent.At low frequencies the
influence of C1 can not be neglected.
Series resistance of C1 that
PBL 38 582
a)
1
4
+Line
b)
R3
820
c)
220
C
3
C2
2
R6
Rs
1
+
C1
Example:
How to connect a
complex network.
220+820//C
-Line
Figure 6. AC-impedance.
is dependent on the temperature and the
quality of the component will cause some
of the line signal to enter pin 4. This
generates a closed loop in the transmitter
amplifier that in it´s turn will create an
active impedance thus lowering the
impedance to the line. The impedance at
high frequencies is set by C2 that also
acts as a RFI suppressor.
In many specifications the
impedance towards the line is specified as
a complex network. See fig. 6. In case a).
the error signal entering pin 4 is set by the
ratio Rs/R3 (909), where in case b). the
ratio at high frequencies will be Rs/220
because the 820resistor is bypassed by
a capacitor. To help up this situation the
complex network capacitor is connected
directly to ground, case c). making the ratio
Rs/220+820and thus lessening the
error signal. Conclusion: Connect like in
case c) when complex impedance is
specified.
DC - characteristic
The DC - characteristic that a
telephone set has to fulfill is mainly given
by the network administrator. Following
parameters are useful to know when the
DC behaviour of the telephone is to be set:
• The voltage of the feeding system
• The line feeding resistance 2 x.......
ohms.
• The maximum current from the line at
zero line length.
• The min. current at which the telephone
has to work (basic function).
• The lowest and highest voltage
permissible across the telephone set.
• The highest voltage that the
telephone may have at different line
currents. Normally set by the
network owners specification.The
lowest voltage for the telephone is
normally set by the voltages that are
needed for the different parts of the
telephone to function. For ex. for
transmitter output amplifier, recei-
ver output amplifier, dialler, speech
switching. R6 will set the slope of the
DC-char. and the rest of the level is
set by some constants in the circuit
as shown in the equation below. The
slope of the DC-char. will also
influence the line length regulation
(when used ) and thus the gain of
both transmitter and receiver. See
the table under gain regulation. R6
also acts as power protection for the
circuit, this must be kept in mind
when low values of R6 are conside-
red. See fig. 7.
VLine 2 + 1. 5 R 6 Iline
Vtelephoneline 1. 5V + Vline
5

5 Page










PáginasTotal 9 Páginas
PDF Descargar[ Datasheet PBL385822SOS.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
PBL385822SOSTelephone Line interface circuit for DECT/ DAM/ CT Unisolated or IsolatedEricsson
Ericsson
PBL385822SOTTelephone Line interface circuit for DECT/ DAM/ CT Unisolated or IsolatedEricsson
Ericsson

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.