No Preview Available ! 62-AFL-030-5-11 Hoja de datos, Descripción, Manual

Power Line Filters
Appliance Filters
62-AL/62-AC Series
Features
I Low-cost plastic case
Tested and found to be
IAW VDE 0565 Part 3
I Compact design requires minimal real estate space
I Suitable for products that must conform
to FCC regulations
I Wide variety of circuit and filtering options
I Good filtering characteristics for both normal mode
and common mode
I Epoxy molded for reliability
I Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page PF53)
Applications
I Personal computers and peripherals
I Digital equipment
I Industrial equipment
I Vending machines
I Home appliances
I Office equipment
Fast-on tab #110
1.220
.629 (31.0)
(16.0)
.177 x .138 (4.5 x 3.5)
.371 1.527 (38.8)
(9.4)
.371
(9.4)
1.573 (40.0)
.994 (24.0)
.657
(16.7)
.374 (9.5)
.263 (6.7)
Circuit Diagrams
Dimensions in inches (mm)
62-A*L
Series
L
CX
R
CY1
CY2
62-A*C
Series
R
L
CX
CY1
CY2
Specifications
Model*
62-AFL-010-3-11
62-AFC-010-3-11
62-AFL-010-5-11
62-AFC-010-5-11
62-AFL-016-3-11
62-AFC-016-3-11
62-AFL-016-5-11
62-AFC-016-5-11
62-AFL-030-3-11
62-AFC-030-3-11
62-AFL-030-5-11
62-AFC-030-5-11
62-AFL-045-3-11
62-AFC-045-3-11
62-AFL-045-5-11
62-AFC-045-5-11
62-AFL-060-3-11
62-AFC-060-3-11
62-AFL-060-5-11
62-AFC-060-5-11
Rated Voltage
(@ 50/60Hz)
250VAC
Rated
Current
1.0A
1.6A
3.0A
4.5A
6.0A
Leakage Current
(Max.)
0.35mA
0.50mA
0.35mA
0.50mA
0.35mA
0.50mA
0.35mA
0.50mA
0.35mA
0.50mA
Capacitance
CY CX
2200pF
3300pF
2200pF
3300pF
2200pF
3300pF
0.1uF
2200pF
3300pF
2200pF
3300pF
* R= w/ Bleeder Resistor
F = w/o Bleeder Resistor
Inductance
(L1)
Temperature
Rise (Max.)
11.0mH
6.0mH
2.4mH
40°C
1.0mH
0.53mH
Note: All types are designed to meet the requirement of UL 1283, CSA 22.2. VDE 0565-3
Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max.
* Available with bleeder resistor
Replace F with R for part number
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF52

1 page





PáginasTotal 2 Páginas
PDF Descargar[ Datasheet 62-AFL-030-5-11.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
62-AFL-030-5-11Power Line Filtersapi
api

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar