XR76115
PowerBlox™
15A Synchronous Step Down COT Regulator
General Description
The XR76115 is a synchronous step-down regulator combining
the controller, drivers, bootstrap diode and MOSFETs in a single
package for point-of-load supplies. The XR76115 has a load
current rating of 15A. A wide 5V to 22V input voltage range
allows for single supply operation from industry standard 5V, 12V
and 19.6V rails.
With a proprietary emulated current mode Constant On-Time
(COT) control scheme, the XR76115 provides extremely fast line
and load transient response using ceramic output capacitors. It
requires no loop compensation, simplifying circuit
implementation and reducing overall component count. The
control loop also provides 0.25% load and 0.12% line regulation
and maintains constant operating frequency. A selectable power
saving mode, allows the user to operate in discontinuous mode
(DCM) at light current loads thereby significantly increasing the
converter efficiency.
A host of protection features, including over-current, over-
temperature, short-circuit and UVLO, help achieve safe
operation under abnormal operating conditions.
The XR76115 is available in a RoHS-compliant, green/halogen-
free space-saving QFN 6x6mm package.
Typical Application
Figure 1: XR76115 Application Diagram
FEATURES
15A Capable Step Down Regulator
4.5V to 5.5V Low VIN Operation
5V to 22V Wide Single Input Voltage
≥0.6V Adjustable Output Voltage
Controller, drivers, bootstrap diode and
MOSFETs integrated in one package
Proprietary Constant On-Time Control
No Loop Compensation Required
Ceramic Output Cap. Stable operation
Programmable 200ns-2µs On-Time
Quasi Constant 200kHz-800kHz Freq.
Selectable CCM or CCM/DCM
Operation
Precision Enable and Power-Good Flag
Programmable Soft-start
6x6mm 37-pin QFN Package
APPLICATIONS
Distributed Power Architecture
Point-of-Load Converters
Power Supply Modules
FPGA, DSP, and Processor Supplies
Base Stations, Switches/Routers, and
Servers
1.220
1.215
1.210
1.205
1.200
1.195
1.190
1.185
1.180
5
10 15
VIN (V)
20
Figure 2: XR76115 line regulation
©2015 Exar Corporation
www.exar.com
Rev 1B

1 page




XR76115 pdf
Pin Assignment
XR76115
Figure 4: XR76115 Pin Assignment, top view
© 2015 Exar Corporation
5/16
www.exar.com
Rev. 1B

5 Page





XR76115 arduino
XR76115
Detailed Operation
The XR76115 uses a synchronous step-down proprietary
emulated current-mode Constant On-Time (COT) control
scheme. The on-time, which is programmed via RON, is
inversely proportional to VIN and maintains a nearly
constant frequency. The emulated current-mode control
allows the use of ceramic output capacitors.
Each switching cycle begins with the high-side (switching)
FET turning on for a preprogrammed time. At the end of
the on-time, the high-side FET is turned off and the low-
side (synchronous) FET is turned on for a preset minimum
time (250ns nominal). This parameter is termed the
Minimum Off-Time. After the minimum off-time the voltage
at the feedback pin FB is compared to an internal voltage
ramp at the feedback comparator. When VFB drops below
the ramp voltage, the high-side FET is turned on and the
cycle repeats. This voltage ramp constitutes an emulated
current ramp and allows for the use of ceramic capacitors,
in addition to other capacitor types, for output filtering.
Enable/Mode
The EN/MODE pin accepts a tri-level signal that is used to
control channel turn-on and turn-off. It also selects
between two modes of operation: ‘Forced CCM’ and
‘DCM/CCM’. If EN is pulled below 1.9V the regulator shuts
down. A voltage between 1.9V and 3V selects the Forced
CCM mode, which will run the converter in continuous
conduction for all load currents. A voltage higher than 3V
selects the DCM/CCM mode, which will run the converter
in discontinuous conduction mode at light loads.
Selecting the Forced CCM Mode
In order to set the controller to operate in Forced CCM, a
voltage between 1.9V and 3.0V must be applied to the
EN/MODE pin. This can be achieved with an external
control signal that meets the above voltage requirement.
Where an external control is not available, the EN/MODE
signal can be derived from VIN. If VIN is well regulated, use
a resistor divider and set the voltage to 2.5V. If VIN varies
over a wide range, the circuit shown in Figure 27 can be
used to generate the required voltage. Note that at VIN of
5.5V to 22V, the nominal Zener voltage is 4.0V to 5.0V
respectively. Therefore, for VIN in the range of 5.5V to 22V,
the circuit shown in Figure 27 will generate voltage at the
EN/MODE pin required for Forced CCM.
Selecting the DCM/CCM Mode
In order to set the controller operation to DCM/CCM, a
voltage between 3.1V and 5.5V must be applied to the
EN/MODE pin. If an external control signal is available, it
can be directly connected to the EN/MODE pin. In
applications where an external control signal is not
available, EN/MODE input can be derived from VIN. If VIN is
well regulated, use a resistor divider and set the voltage to
4.0V. If VIN varies over a wide range, the circuit shown in
Figure 28 can be used to generate the required voltage.
Figure 27: Selecting Forced CCM by deriving EN/MODE
from VIN
Figure 28: Selecting DCM/CCM by deriving EN/MODE
from VIN
Programming the On-Time
The on-time TON is programmed via resistor RON according
to following equation:
2.5 10
3 10
TON is calculated from:
.
Where:
f is the desired switching frequency at nominal IOUT
© 2015 Exar Corporation
11/16
www.exar.com
Rev. 1B

11 Page







PáginasTotal 16 Páginas
PDF Descargar[ Datasheet XR76115.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
XR761128A and 12A Synchronous Step Down COT RegulatorExar
Exar
XR7611515A Synchronous Step Down COT RegulatorExar
Exar
XR7611615A and 20A Synchronous Step-Down COT RegulatorsExar
Exar
XR7611715A Synchronous Step-Down COT RegulatorExar
Exar

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar